{"id":34724,"date":"2024-12-24T01:31:26","date_gmt":"2024-12-24T07:31:26","guid":{"rendered":"https:\/\/www.logicbus.com.mx\/blog\/?p=34724"},"modified":"2026-02-03T11:13:04","modified_gmt":"2026-02-03T17:13:04","slug":"logica-relay-relevador","status":"publish","type":"post","link":"https:\/\/www.logicbus.com.mx\/blog\/logica-relay-relevador\/","title":{"rendered":"L\u00f3gica del Relay o Relevador"},"content":{"rendered":"<p style=\"text-align: justify;\">La l\u00f3gica del Relay o relevador tiene que ver con el cableado de <a href=\"https:\/\/www.logicbus.com.mx\/blog\/tipos-de-reles-mecanicos\/\">rel\u00e9s<\/a> para aplicaciones de conmutaci\u00f3n l\u00f3gica.\u00a0Este articulo muestra varias formas sencillas de cablear un rel\u00e9 para diversas aplicaciones.\u00a0Conocer la l\u00f3gica del <a href=\"https:\/\/www.logicbus.com.mx\/blog\/reles-de-estado-solido\/\">relevador<\/a> le proporciona una gu\u00eda para el uso de controladores de rel\u00e9 NCD y c\u00f3mo se pueden cablear para muchos tipos de aplicaciones. Utilice esta l\u00f3gica para controlar la direcci\u00f3n de avance o retroceso de los motores, controlar luces mediante rel\u00e9s en aplicaciones est\u00e1ndar, as\u00ed como en aplicaciones de conmutaci\u00f3n de 3 v\u00edas. Esta gu\u00eda de l\u00f3gica del relay ayuda a demostrar las mejores formas de conectar controladores de rel\u00e9s NCD en aplicaciones de control del mundo real.<\/p>\n<p style=\"text-align: justify;\">La conexi\u00f3n COM (com\u00fan) de un rel\u00e9 es la parte del rel\u00e9 que se mueve.\u00a0Cuando un rel\u00e9 est\u00e1 apagado, el COM\u00daN est\u00e1 conectado al NC (normalmente cerrado).\u00a0La conexi\u00f3n NO (normalmente abierta) del rel\u00e9 no se conecta hasta que el rel\u00e9 se enciende.\u00a0Cuando el rel\u00e9 se enciende, el COM\u00daN pasa de NC a NO.\u00a0Los rel\u00e9s mec\u00e1nicos crean un sonido de clic que indica movimiento en el terminal COM\u00daN.\u00a0No todos los rel\u00e9s tienen una conexi\u00f3n normalmente cerrada.\u00a0Por ejemplo, los rel\u00e9s de 30 A no suelen tener una conexi\u00f3n normalidad cerrada, solo normalmente abierta por seguridad.\u00a0Actualmente no son comunes los rel\u00e9s de estado s\u00f3lido con una conexi\u00f3n normalmente cerrada pero es posible utilizar dos rel\u00e9s para crear una condici\u00f3n normalmente cerrada.<\/p>\n<h2><strong>El rel\u00e9 activa la luz<\/strong><\/h2>\n<p style=\"text-align: justify;\">Este ejemplo demuestra c\u00f3mo se puede utilizar un rel\u00e9 para activar una bombilla.\u00a0Cuando el rel\u00e9 se enciende, la luz se enciende.\u00a0Solo un cable de alimentaci\u00f3n se conmuta con esta muestra utilizando las conexiones COM (com\u00fan) y NO (normalmente abierto) de un rel\u00e9.<\/p>\n<p><img decoding=\"async\" class=\" wp-image-34745 aligncenter\" src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/image4-300x197.gif\" alt=\"\" width=\"50%\" srcset=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/image4-300x197.gif 300w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/image4-18x13.gif 18w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/p>\n<h2><strong>El rel\u00e9 desactiva la luz (Not)<\/strong><\/h2>\n<p style=\"text-align: justify;\">Este ejemplo demuestra c\u00f3mo se puede utilizar un rel\u00e9 para desactivar una bombilla.\u00a0Cuando el rel\u00e9 se apaga, la luz se enciende.\u00a0Solo un cable de alimentaci\u00f3n se conmuta con esta muestra utilizando las conexiones COM (com\u00fan) y NO (normalmente abierto) de un rel\u00e9.<\/p>\n<p><img decoding=\"async\" class=\" wp-image-34730 aligncenter\" src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/light2-300x218.png\" alt=\"\" width=\"50%\" srcset=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/light2-300x218.png 300w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/light2-18x13.png 18w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/light2.png 498w\" sizes=\"(max-width: 300px) 100vw, 300px\" \/><\/p>\n<h2><strong>Se requieren 2 rel\u00e9s para activar la luz (And)<\/strong><\/h2>\n<p><span style=\"font-weight: 400;\">Este ejemplo demuestra c\u00f3mo se conectan dos rel\u00e9s en serie para activar una luz.\u00a0Ambos rel\u00e9s deben estar activados para que se encienda la luz.<\/span><\/p>\n<p><img decoding=\"async\" class=\" wp-image-34746 aligncenter\" src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/image5-300x137.gif\" alt=\"\" width=\"431\" height=\"197\" srcset=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/image5-300x137.gif 300w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/image5-20x10.gif 20w\" sizes=\"(max-width: 431px) 100vw, 431px\" \/><\/p>\n<h2><strong>Se requieren 3 rel\u00e9s para activar la luz<\/strong><\/h2>\n<p><span style=\"font-weight: 400;\">Este ejemplo demuestra c\u00f3mo se conectan tres rel\u00e9s en serie para activar una luz.\u00a0Los tres rel\u00e9s deben estar activados para que se encienda la luz.<\/span><\/p>\n<p><img decoding=\"async\" class=\" wp-image-34749 aligncenter\" src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/image8-300x124.gif\" alt=\"\" width=\"519\" height=\"214\" \/><\/p>\n<h2><strong>Cualquiera de los rel\u00e9s activa la luz (Or)<\/strong><\/h2>\n<p style=\"text-align: justify;\">Este ejemplo demuestra c\u00f3mo cualquiera de los dos rel\u00e9s activar\u00e1 una luz.\u00a0Encienda cualquiera de los rel\u00e9s y la luz se enciende.\u00a0Ambos rel\u00e9s deben estar apagados para que la luz se apague.<\/p>\n<p><img decoding=\"async\" class=\"wp-image-34748 aligncenter\" src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/image7-300x146.gif\" alt=\"\" width=\"406\" height=\"198\" srcset=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/image7-300x146.gif 300w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/image7-20x10.gif 20w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/image7-80x40.gif 80w\" sizes=\"(max-width: 406px) 100vw, 406px\" \/><\/p>\n<h2><strong>Interruptor de luz de 3 v\u00edas (toggle)<\/strong><\/h2>\n<p style=\"text-align: justify;\">Este ejemplo demuestra c\u00f3mo se puede utilizar un <a href=\"https:\/\/www.electricity-magnetism.org\/es\/como-funcionan-los-interruptores-electricos\/\" rel=\"nofollow\">interruptor <\/a>de luz de 3 v\u00edas para activar una luz.\u00a0Un interruptor de luz de 3 v\u00edas se encuentra a menudo en su casa donde se pueden usar dos interruptores de luz para activar una sola luz.\u00a0Esta muestra es exactamente igual a un interruptor de luz de 3 v\u00edas, la \u00fanica diferencia es que cada interruptor f\u00edsico es reemplazado por un rel\u00e9.\u00a0Operacionalmente, funciona de la misma manera.\u00a0Cada activaci\u00f3n de rel\u00e9 har\u00e1 que la luz se encienda.\u00a0Cambiar dos rel\u00e9s a la vez es como accionar 2 interruptores a la vez con el mismo resultado.\u00a0Esta muestra es particularmente \u00fatil ya que puede reemplazar un rel\u00e9 (como se muestra en el diagrama) con un interruptor de luz f\u00edsico.\u00a0Esto permitir\u00e1 que una computadora controle una luz, as\u00ed como el funcionamiento manual de una luz.\u00a0Si se usa correctamente, este puede ser uno de los diagramas m\u00e1s valiosos que ofrecemos en esta p\u00e1gina.<\/p>\n<p><img decoding=\"async\" class=\" wp-image-34743 aligncenter\" src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/image2-300x170.gif\" alt=\"\" width=\"407\" height=\"231\" srcset=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/image2-300x170.gif 300w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/image2-20x10.gif 20w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/image2-30x17.gif 30w\" sizes=\"(max-width: 407px) 100vw, 407px\" \/><\/p>\n<h2><strong>Direcci\u00f3n del motor de control de rel\u00e9s<\/strong><\/h2>\n<p style=\"text-align: justify;\">Este ejemplo demuestra c\u00f3mo controlar la direcci\u00f3n de un motor de CC utilizando 2 rel\u00e9s.\u00a0El frenado se logra conectando ambos terminales del motor a una conexi\u00f3n el\u00e9ctrica com\u00fan (<a href=\"https:\/\/es.khanacademy.org\/science\/physics\/magnetic-forces-and-magnetic-fields\/magnetic-flux-faradays-law\/a\/what-is-faradays-law\" rel=\"nofollow\">Ley de Faraday<\/a>).\u00a0Los capacitores que se muestran pueden no ser necesarios para motores peque\u00f1os, pero si tiene problemas con los rel\u00e9s que se apagan solos, se requerir\u00e1 el <a href=\"https:\/\/www.logicbus.com.mx\/blog\/tutorial-sobre-capacitores\/\">capacitor<\/a> de supresi\u00f3n de inducci\u00f3n.\u00a0El capacitor de .1uF ayuda a suprimir el ruido electr\u00f3nico si la bater\u00eda fuera a ser utilizada por dispositivos sensibles (como radios \/ amplificadores).<\/p>\n<p><img decoding=\"async\" class=\" wp-image-34742 aligncenter\" src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/image1-3-300x201.png\" alt=\"\" width=\"495\" height=\"332\" srcset=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/image1-3-300x201.png 300w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/image1-3-18x13.png 18w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/image1-3.png 703w\" sizes=\"(max-width: 495px) 100vw, 495px\" \/><\/p>\n<h2><strong>Construya un controlador H-Bridge con rel\u00e9s de estado s\u00f3lido<\/strong><\/h2>\n<p style=\"text-align: justify;\">Controle la direcci\u00f3n de un motor de CC usando cuatro rel\u00e9s de estado s\u00f3lido usando el siguiente diagrama de cableado.\u00a0Este dise\u00f1o usa cuatro rel\u00e9s en una configuraci\u00f3n H-Bridge, que se usa para controlar la polaridad del motor.\u00a0Diferentes combinaciones de rel\u00e9 &#8220;encendido&#8221; afectan al motor de diferentes maneras, incluyendo avance, retroceso, frenado y flotaci\u00f3n.\u00a0La flotaci\u00f3n esencialmente desconecta la energ\u00eda del motor, lo que permite que se detenga de forma natural.\u00a0El frenado conecta los cables del motor a voltajes de suministro positivos o negativos, lo que obliga al motor de CC a detenerse de inmediato.\u00a0El frenado a positivo descargar\u00e1 la energ\u00eda del motor al positivo de la fuente de alimentaci\u00f3n.\u00a0El frenado en negativo descargar\u00e1 la energ\u00eda del motor en el negativo de la fuente de alimentaci\u00f3n (que generalmente se prefiere para algunas aplicaciones).\u00a0Adelante conectar\u00e1 el motor positivo a V + y el motor negativo a tierra.<\/p>\n<p style=\"text-align: justify;\">No todas las combinaciones de rel\u00e9s son seguras.\u00a0Debido a que esta es una configuraci\u00f3n de puente H, ciertas combinaciones de rel\u00e9s cortocircuitar\u00e1n ambos rel\u00e9s, causando da\u00f1os permanentes.\u00a0Por esta raz\u00f3n, le recomendamos encarecidamente que utilice un fusible con una clasificaci\u00f3n adecuada para el motor y los rel\u00e9s.\u00a0Recomendamos encarecidamente desarrollar software con V + desconectado.\u00a0Aseg\u00farese de que los rel\u00e9s sigan la tabla en la parte inferior del diagrama de cableado ANTES de aplicar energ\u00eda a V +.\u00a0Algunas combinaciones de rel\u00e9s simplemente no son v\u00e1lidas.\u00a0Por lo general, parar\u00e1n el motor, pero no son relevantes ni recomendados.<\/p>\n<p><img decoding=\"async\" class=\" wp-image-34759 aligncenter\" src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/image3-4-225x300.png\" alt=\"\" width=\"701\" height=\"935\" srcset=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/image3-4-225x300.png 225w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/image3-4-768x1023.png 768w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/image3-4-1153x1536.png 1153w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/image3-4.png 1350w\" sizes=\"(max-width: 701px) 100vw, 701px\" \/><\/p>\n<h2 style=\"text-align: center;\">Cont\u00e1ctanos<\/h2>\n<h3 style=\"text-align: center;\"><a href=\"https:\/\/tienda.logicbus.com.mx\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" class=\"card-review alignnone\" title=\"Tienda en linea\" src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/11\/tienda.png \" alt=\"\" width=\"102\" height=\"102\" \/><\/a><a href=\"https:\/\/www.logicbus.com.mx\/\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" class=\"card-review alignnone\" title=\"Logicbus\" src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/11\/www.png \" alt=\"\" width=\"104\" height=\"104\" \/><\/a><a href=\"https:\/\/www.logicbus.com.mx\/soporte\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" class=\"card-review alignnone\" title=\"Soporte\" src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/11\/soporte.png \" alt=\"\" width=\"106\" height=\"106\" \/><\/a><a href=\"https:\/\/api.whatsapp.com\/send?phone=525554316718&amp;text=Hola%20Logicbus,me%20gustar%C3%ADa%20solicitar%20informaci%C3%B3n\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" class=\"card-review alignnone\" title=\"Whatsapp\" src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/11\/wa.png \" alt=\"\" width=\"103\" height=\"103\" \/><\/a><a href=\"https:\/\/www.logicbus.com.mx\/contacto\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" class=\"card-review alignnone\" title=\"Contacto\" src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/11\/contacto.png \" alt=\"\" width=\"115\" height=\"115\" \/><\/a><a href=\"https:\/\/www.logicbus.com.mx\/soluciones-en-la-industria-logicbus.php\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" class=\"card-review alignnone\" title=\"Soluciones\" src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/11\/soluciones.png \" alt=\"\" width=\"106\" height=\"106\" \/><\/a><\/h3>\n<p style=\"text-align: center;\"><a href=\"mailto:ventas@logicbus.com\">ventas@logicbus.com<\/a>\u00a0 \u00a0 \u00a0 |\u00a0 \u00a0 \u00a0\u00a0<a href=\"mailto:soporte@logicbus.com\">soporte@logicbus.com<\/a>\u00a0 \u00a0 \u00a0 |\u00a0 \u00a0 \u00a0\u00a0<a href=\"https:\/\/api.whatsapp.com\/send?phone=525554316718&amp;text=Hola%20Logicbus,me%20gustar%C3%ADa%20solicitar%20informaci%C3%B3n\">55-5431-67-18<\/a>\u00a0 \u00a0 |\u00a0 \u00a0 \u00a0\u00a0 <a href=\"https:\/\/tawk.to\/chat\/5ca674ff1de11b6e3b06f73d\/default\">Iniciar conversaci\u00f3n<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>La l\u00f3gica del Relay o relevador tiene que ver con el cableado de rel\u00e9s para aplicaciones de conmutaci\u00f3n l\u00f3gica.\u00a0Este articulo muestra varias formas sencillas de cablear un rel\u00e9 para diversas aplicaciones.\u00a0Conocer la l\u00f3gica del relevador le proporciona una gu\u00eda para el uso de controladores de rel\u00e9 NCD y c\u00f3mo se pueden cablear para muchos tipos [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":41469,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[71,5535,5767,4713],"tags":[5590,5569,5550],"class_list":["post-34724","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articulos","category-informacion-tecnica","category-plcs-y-convertidores-de-protocolo","category-publicaciones-en-espanol","tag-convertidores-de-protocolo","tag-national-control-devices","tag-pcs-y-comunicaciones-industriales"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.1 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>L\u00f3gica del Relay o Relevador &#8211; Blog Logicbus<\/title>\n<meta name=\"description\" content=\"Esta gu\u00eda de l\u00f3gica del relay ayuda a demostrar c\u00f3mo conectar controladores de rel\u00e9s NCD en aplicaciones de control del mundo real.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.logicbus.com.mx\/blog\/logica-relay-relevador\/\" \/>\n<meta property=\"og:locale\" content=\"es_MX\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"L\u00f3gica del Relay o Relevador &#8211; Blog Logicbus\" \/>\n<meta property=\"og:description\" content=\"Esta gu\u00eda de l\u00f3gica del relay ayuda a demostrar c\u00f3mo conectar controladores de rel\u00e9s NCD en aplicaciones de control del mundo real.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.logicbus.com.mx\/blog\/logica-relay-relevador\/\" \/>\n<meta property=\"og:site_name\" content=\"Blog Logicbus\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/logicbus\/\" \/>\n<meta property=\"article:published_time\" content=\"2024-12-24T07:31:26+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-02-03T17:13:04+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2019\/07\/Lo\u0301gica-del-Relay.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1920\" \/>\n\t<meta property=\"og:image:height\" content=\"1080\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Logicbus\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"Logicbus\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"8 minutos\" \/>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"L\u00f3gica del Relay o Relevador &#8211; Blog Logicbus","description":"Esta gu\u00eda de l\u00f3gica del relay ayuda a demostrar c\u00f3mo conectar controladores de rel\u00e9s NCD en aplicaciones de control del mundo real.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.logicbus.com.mx\/blog\/logica-relay-relevador\/","og_locale":"es_MX","og_type":"article","og_title":"L\u00f3gica del Relay o Relevador &#8211; Blog Logicbus","og_description":"Esta gu\u00eda de l\u00f3gica del relay ayuda a demostrar c\u00f3mo conectar controladores de rel\u00e9s NCD en aplicaciones de control del mundo real.","og_url":"https:\/\/www.logicbus.com.mx\/blog\/logica-relay-relevador\/","og_site_name":"Blog Logicbus","article_publisher":"https:\/\/www.facebook.com\/logicbus\/","article_published_time":"2024-12-24T07:31:26+00:00","article_modified_time":"2026-02-03T17:13:04+00:00","og_image":[{"width":1920,"height":1080,"url":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2019\/07\/Lo\u0301gica-del-Relay.png","type":"image\/png"}],"author":"Logicbus","twitter_misc":{"Escrito por":"Logicbus","Tiempo de lectura":"8 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.logicbus.com.mx\/blog\/logica-relay-relevador\/#article","isPartOf":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/logica-relay-relevador\/"},"author":{"name":"Logicbus","@id":"https:\/\/www.logicbus.com.mx\/blog\/#\/schema\/person\/42451dd47a6fc9e56bb0386ab20bffd5"},"headline":"L\u00f3gica del Relay o Relevador","datePublished":"2024-12-24T07:31:26+00:00","dateModified":"2026-02-03T17:13:04+00:00","mainEntityOfPage":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/logica-relay-relevador\/"},"wordCount":1082,"publisher":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/#organization"},"image":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/logica-relay-relevador\/#primaryimage"},"thumbnailUrl":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2019\/07\/Lo\u0301gica-del-Relay.png","keywords":["Convertidores de Protocolo","NATIONAL CONTROL DEVICES","PC's y Comunicaciones Industriales"],"articleSection":["Articulos","Informaci\u00f3n T\u00e9cnica","PLCs y Convertidores de protocolo","Publicaciones en Espa\u00f1ol"],"inLanguage":"es"},{"@type":"WebPage","@id":"https:\/\/www.logicbus.com.mx\/blog\/logica-relay-relevador\/","url":"https:\/\/www.logicbus.com.mx\/blog\/logica-relay-relevador\/","name":"L\u00f3gica del Relay o Relevador &#8211; Blog Logicbus","isPartOf":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/logica-relay-relevador\/#primaryimage"},"image":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/logica-relay-relevador\/#primaryimage"},"thumbnailUrl":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2019\/07\/Lo\u0301gica-del-Relay.png","datePublished":"2024-12-24T07:31:26+00:00","dateModified":"2026-02-03T17:13:04+00:00","description":"Esta gu\u00eda de l\u00f3gica del relay ayuda a demostrar c\u00f3mo conectar controladores de rel\u00e9s NCD en aplicaciones de control del mundo real.","breadcrumb":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/logica-relay-relevador\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.logicbus.com.mx\/blog\/logica-relay-relevador\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.logicbus.com.mx\/blog\/logica-relay-relevador\/#primaryimage","url":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2019\/07\/Lo\u0301gica-del-Relay.png","contentUrl":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2019\/07\/Lo\u0301gica-del-Relay.png","width":1920,"height":1080,"caption":"Imagen sobre l\u00f3gica del Relay"},{"@type":"BreadcrumbList","@id":"https:\/\/www.logicbus.com.mx\/blog\/logica-relay-relevador\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Inicio","item":"https:\/\/www.logicbus.com.mx\/blog\/"},{"@type":"ListItem","position":2,"name":"L\u00f3gica del Relay o Relevador"}]},{"@type":"WebSite","@id":"https:\/\/www.logicbus.com.mx\/blog\/#website","url":"https:\/\/www.logicbus.com.mx\/blog\/","name":"Blog Logicbus","description":"Logicbus Blog ofrece informaci\u00f3n detallada sobre el control de procesos, sus tipos, elementos e importancia.","publisher":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.logicbus.com.mx\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/www.logicbus.com.mx\/blog\/#organization","name":"Logicbus Blog","url":"https:\/\/www.logicbus.com.mx\/blog\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.logicbus.com.mx\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/logo-logicbus-blog.png","contentUrl":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/logo-logicbus-blog.png","width":1761,"height":546,"caption":"Logicbus Blog"},"image":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/logicbus\/","https:\/\/x.com\/Logicbus"]},{"@type":"Person","@id":"https:\/\/www.logicbus.com.mx\/blog\/#\/schema\/person\/42451dd47a6fc9e56bb0386ab20bffd5","name":"Logicbus","image":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/JosueCetina-96x96.png","url":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/JosueCetina-96x96.png","contentUrl":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/JosueCetina-96x96.png","caption":"Logicbus"},"sameAs":["https:\/\/www.logicbus.com.mx\/blog","it@logicbus.com"],"url":"https:\/\/www.logicbus.com.mx\/blog\/author\/itlogicbus-com\/"}]}},"_links":{"self":[{"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/posts\/34724","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/comments?post=34724"}],"version-history":[{"count":0,"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/posts\/34724\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/media\/41469"}],"wp:attachment":[{"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/media?parent=34724"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/categories?post=34724"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/tags?post=34724"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}