{"id":36642,"date":"2021-05-04T23:17:15","date_gmt":"2021-05-04T23:17:15","guid":{"rendered":"https:\/\/www.logicbus.com.mx\/blog\/?p=36642"},"modified":"2022-09-27T14:41:10","modified_gmt":"2022-09-27T14:41:10","slug":"celdas-de-carga-instalacion-indicadores-transmisores-peso","status":"publish","type":"post","link":"https:\/\/www.logicbus.com.mx\/blog\/celdas-de-carga-instalacion-indicadores-transmisores-peso\/","title":{"rendered":"Instalaci\u00f3n Celdas de Carga. 8.- Normas de instalaci\u00f3n de indicadores y transmisores de peso"},"content":{"rendered":"<p>&nbsp;<\/p>\n<h2 style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Instalaci\u00f3n de Celdas de Carga<\/span><\/h2>\n<h6><strong>Tema 8 &#8211; Normas de instalaci\u00f3n de indicadores y transmisores de peso<\/strong><\/h6>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Normas para la correcta instalaci\u00f3n de los equipos electr\u00f3nicos: indicadores y transmisores de peso: <\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">El cable de las celdas de carga debe ir solo y no debe pasar por canaletas junto con otros cables. <\/span><span style=\"font-weight: 400;\">Se recomienda conectarlo directamente al indicador o transmisor de peso sin interrupciones y sin terminales a tornillo.<\/span><\/p>\n<p><img decoding=\"async\" class=\"wp-image-37805 aligncenter\" src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/05\/normas-instalacion-1-733-300x184.jpg\" alt=\"mant\u00e9n el cable de la celda aislado y sin interrupciones - celdas de carga - Laumas \" width=\"554\" height=\"340\" srcset=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/05\/normas-instalacion-1-733-300x184.jpg 300w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/05\/normas-instalacion-1-733-150x92.jpg 150w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/05\/normas-instalacion-1-733.jpg 733w\" sizes=\"(max-width: 554px) 100vw, 554px\" \/> <img decoding=\"async\" class=\" wp-image-37809 aligncenter\" src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/05\/normas-instalacion-2-733-300x184.jpg\" alt=\"mant\u00e9n el cable de la celda aislado y sin interrupciones correcto - celdas de carga - Laumas\" width=\"553\" height=\"340\" srcset=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/05\/normas-instalacion-2-733-300x184.jpg 300w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/05\/normas-instalacion-2-733-150x92.jpg 150w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/05\/normas-instalacion-2-733.jpg 733w\" sizes=\"(max-width: 553px) 100vw, 553px\" \/><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Se recomienda evitar la instalaci\u00f3n de los equipos electr\u00f3nicos en un tablero en el que haya inversores.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Si es inevitable, se debe instalar filtros espec\u00edficos e interponer chapas de separaci\u00f3n.<\/span><\/p>\n<p><img decoding=\"async\" class=\" wp-image-37812 aligncenter\" src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/05\/normas-instalacion-3-733-300x184.jpg\" alt=\"aisle los equipos electr\u00f3nicos de los invertidores \" width=\"539\" height=\"331\" srcset=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/05\/normas-instalacion-3-733-300x184.jpg 300w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/05\/normas-instalacion-3-733-150x92.jpg 150w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/05\/normas-instalacion-3-733.jpg 733w\" sizes=\"(max-width: 539px) 100vw, 539px\" \/> <img decoding=\"async\" class=\" wp-image-37814 aligncenter\" src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/05\/normas-instalacion-4-733-300x184.jpg\" alt=\"aisle los equipos electr\u00f3nicos de los invertidores correctamente\" width=\"540\" height=\"331\" srcset=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/05\/normas-instalacion-4-733-300x184.jpg 300w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/05\/normas-instalacion-4-733-150x92.jpg 150w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/05\/normas-instalacion-4-733.jpg 733w\" sizes=\"(max-width: 540px) 100vw, 540px\" \/><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Si fuera necesario alimentar los equipos a 127 volts con corriente alterna utilice un transformador de 330 a 127 volts. Evite utilizar una de las fases de la red a 330 volts y el neutro.<\/span><\/p>\n<p><img decoding=\"async\" class=\" wp-image-37816 aligncenter\" src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/05\/normas-instalacion-5-733-300x184.jpg\" alt=\"en caso de linea a 380 VAC, utilice un transformador - celdas de carga - Laumas\" width=\"538\" height=\"330\" srcset=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/05\/normas-instalacion-5-733-300x184.jpg 300w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/05\/normas-instalacion-5-733-150x92.jpg 150w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/05\/normas-instalacion-5-733.jpg 733w\" sizes=\"(max-width: 538px) 100vw, 538px\" \/><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">El responsable del panel el\u00e9ctrico deber\u00e1 montar todas las protecciones el\u00e9ctricas necesarias para la instalaci\u00f3n.<\/span><\/p>\n<p><img decoding=\"async\" class=\"wp-image-37837 aligncenter\" src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/05\/Sin-titulo-1-1.gif\" alt=\"utilice protecciones electricas - celdas de carga - Laumas\" width=\"551\" height=\"300\" \/><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Es recomendable mantener los <a href=\"https:\/\/tienda.logicbus.com.mx\/Celdas-de-Carga-Laumas_c_4110.html\">equipos<\/a> siempre alimentados para evitar la formaci\u00f3n de condensaci\u00f3n.<\/span><\/p>\n<p><img decoding=\"async\" class=\" wp-image-37840 aligncenter\" src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/05\/normas-instalacion-6-733-300x184.jpg\" alt=\"mantenga los equipos siempre alimentados para evitar la formaci\u00f3n de condensaci\u00f3n - celdas de carga - Laumas \" width=\"545\" height=\"334\" srcset=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/05\/normas-instalacion-6-733-300x184.jpg 300w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/05\/normas-instalacion-6-733-150x92.jpg 150w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/05\/normas-instalacion-6-733.jpg 733w\" sizes=\"(max-width: 545px) 100vw, 545px\" \/><\/p>\n<p>Si tienes dudas en alg\u00fan punto o requieres mas ayuda con gusto te asesoramos en <a href=\"mailto:soporte@logicbus.com\">soporte@logicbus.com<\/a><\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>&nbsp; Instalaci\u00f3n de Celdas de Carga Tema 8 &#8211; Normas de instalaci\u00f3n de indicadores y transmisores de peso Normas para la correcta instalaci\u00f3n de los equipos electr\u00f3nicos: indicadores y transmisores de peso: El cable de las celdas de carga debe ir solo y no debe pasar por canaletas junto con otros cables. Se recomienda conectarlo [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":36649,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[5534,71,5765],"tags":[5545,5552],"class_list":["post-36642","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-aplicaciones-de-automatizacion-en-la-industria","category-articulos","category-celdas-de-carga-y-electronica-de-pesaje","tag-celda-de-carga","tag-sensores-y-transductores"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Normas de instalaci\u00f3n de indicadores y transmisores &#8211; Blog Logicbus<\/title>\n<meta name=\"description\" content=\"Normas de instalaci\u00f3n de indicadores y transmisores de peso.Normas para la correcta instalaci\u00f3n de los equipos electr\u00f3nicos: indicadores y transmisores de..\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.logicbus.com.mx\/blog\/celdas-de-carga-instalacion-indicadores-transmisores-peso\/\" \/>\n<meta property=\"og:locale\" content=\"es_MX\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Normas de instalaci\u00f3n de indicadores y transmisores &#8211; Blog Logicbus\" \/>\n<meta property=\"og:description\" content=\"Normas de instalaci\u00f3n de indicadores y transmisores de peso.Normas para la correcta instalaci\u00f3n de los equipos electr\u00f3nicos: indicadores y transmisores de..\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.logicbus.com.mx\/blog\/celdas-de-carga-instalacion-indicadores-transmisores-peso\/\" \/>\n<meta property=\"og:site_name\" content=\"Blog Logicbus\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/logicbus\/\" \/>\n<meta property=\"article:published_time\" content=\"2021-05-04T23:17:15+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-09-27T14:41:10+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/04\/2021-04-23_12-07-44-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"733\" \/>\n\t<meta property=\"og:image:height\" content=\"450\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Josue Cetina\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"Josue Cetina\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"1 minuto\" \/>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Normas de instalaci\u00f3n de indicadores y transmisores &#8211; Blog Logicbus","description":"Normas de instalaci\u00f3n de indicadores y transmisores de peso.Normas para la correcta instalaci\u00f3n de los equipos electr\u00f3nicos: indicadores y transmisores de..","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.logicbus.com.mx\/blog\/celdas-de-carga-instalacion-indicadores-transmisores-peso\/","og_locale":"es_MX","og_type":"article","og_title":"Normas de instalaci\u00f3n de indicadores y transmisores &#8211; Blog Logicbus","og_description":"Normas de instalaci\u00f3n de indicadores y transmisores de peso.Normas para la correcta instalaci\u00f3n de los equipos electr\u00f3nicos: indicadores y transmisores de..","og_url":"https:\/\/www.logicbus.com.mx\/blog\/celdas-de-carga-instalacion-indicadores-transmisores-peso\/","og_site_name":"Blog Logicbus","article_publisher":"https:\/\/www.facebook.com\/logicbus\/","article_published_time":"2021-05-04T23:17:15+00:00","article_modified_time":"2022-09-27T14:41:10+00:00","og_image":[{"width":733,"height":450,"url":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/04\/2021-04-23_12-07-44-1.jpg","type":"image\/jpeg"}],"author":"Josue Cetina","twitter_misc":{"Escrito por":"Josue Cetina","Tiempo de lectura":"1 minuto"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.logicbus.com.mx\/blog\/celdas-de-carga-instalacion-indicadores-transmisores-peso\/#article","isPartOf":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/celdas-de-carga-instalacion-indicadores-transmisores-peso\/"},"author":{"name":"Josue Cetina","@id":"https:\/\/www.logicbus.com.mx\/blog\/#\/schema\/person\/d2f308e65be01c1b9ab007719614b6a7"},"headline":"Instalaci\u00f3n Celdas de Carga. 8.- Normas de instalaci\u00f3n de indicadores y transmisores de peso","datePublished":"2021-05-04T23:17:15+00:00","dateModified":"2022-09-27T14:41:10+00:00","mainEntityOfPage":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/celdas-de-carga-instalacion-indicadores-transmisores-peso\/"},"wordCount":206,"commentCount":0,"publisher":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/#organization"},"image":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/celdas-de-carga-instalacion-indicadores-transmisores-peso\/#primaryimage"},"thumbnailUrl":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/04\/2021-04-23_12-07-44-1.jpg","keywords":["celda de carga","Sensores y Transductores"],"articleSection":["Aplicaciones","Articulos","Celdas de Carga y electr\u00f3nica de pesaje"],"inLanguage":"es","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.logicbus.com.mx\/blog\/celdas-de-carga-instalacion-indicadores-transmisores-peso\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.logicbus.com.mx\/blog\/celdas-de-carga-instalacion-indicadores-transmisores-peso\/","url":"https:\/\/www.logicbus.com.mx\/blog\/celdas-de-carga-instalacion-indicadores-transmisores-peso\/","name":"Normas de instalaci\u00f3n de indicadores y transmisores &#8211; Blog Logicbus","isPartOf":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/celdas-de-carga-instalacion-indicadores-transmisores-peso\/#primaryimage"},"image":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/celdas-de-carga-instalacion-indicadores-transmisores-peso\/#primaryimage"},"thumbnailUrl":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/04\/2021-04-23_12-07-44-1.jpg","datePublished":"2021-05-04T23:17:15+00:00","dateModified":"2022-09-27T14:41:10+00:00","description":"Normas de instalaci\u00f3n de indicadores y transmisores de peso.Normas para la correcta instalaci\u00f3n de los equipos electr\u00f3nicos: indicadores y transmisores de..","breadcrumb":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/celdas-de-carga-instalacion-indicadores-transmisores-peso\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.logicbus.com.mx\/blog\/celdas-de-carga-instalacion-indicadores-transmisores-peso\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.logicbus.com.mx\/blog\/celdas-de-carga-instalacion-indicadores-transmisores-peso\/#primaryimage","url":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/04\/2021-04-23_12-07-44-1.jpg","contentUrl":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/04\/2021-04-23_12-07-44-1.jpg","width":733,"height":450},{"@type":"BreadcrumbList","@id":"https:\/\/www.logicbus.com.mx\/blog\/celdas-de-carga-instalacion-indicadores-transmisores-peso\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Inicio","item":"https:\/\/www.logicbus.com.mx\/blog\/"},{"@type":"ListItem","position":2,"name":"Instalaci\u00f3n Celdas de Carga. 8.- Normas de instalaci\u00f3n de indicadores y transmisores de peso"}]},{"@type":"WebSite","@id":"https:\/\/www.logicbus.com.mx\/blog\/#website","url":"https:\/\/www.logicbus.com.mx\/blog\/","name":"Blog Logicbus","description":"Logicbus Blog ofrece informaci\u00f3n detallada sobre el control de procesos, sus tipos, elementos e importancia.","publisher":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.logicbus.com.mx\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/www.logicbus.com.mx\/blog\/#organization","name":"Logicbus Blog","url":"https:\/\/www.logicbus.com.mx\/blog\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.logicbus.com.mx\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/logo-logicbus-blog.png","contentUrl":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/logo-logicbus-blog.png","width":1761,"height":546,"caption":"Logicbus Blog"},"image":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/logicbus\/","https:\/\/x.com\/Logicbus"]},{"@type":"Person","@id":"https:\/\/www.logicbus.com.mx\/blog\/#\/schema\/person\/d2f308e65be01c1b9ab007719614b6a7","name":"Josue Cetina","image":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/JosueCetina-96x96.png","url":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/JosueCetina-96x96.png","contentUrl":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/JosueCetina-96x96.png","caption":"Josue Cetina"},"url":"https:\/\/www.logicbus.com.mx\/blog\/author\/josue-cetina\/"}]}},"_links":{"self":[{"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/posts\/36642","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/comments?post=36642"}],"version-history":[{"count":0,"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/posts\/36642\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/media\/36649"}],"wp:attachment":[{"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/media?parent=36642"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/categories?post=36642"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/tags?post=36642"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}