{"id":38216,"date":"2021-07-29T16:24:10","date_gmt":"2021-07-29T16:24:10","guid":{"rendered":"https:\/\/www.logicbus.com.mx\/blog\/?p=38216"},"modified":"2022-09-27T15:42:20","modified_gmt":"2022-09-27T15:42:20","slug":"como-conectar-una-hmi-y-un-plc-fatek","status":"publish","type":"post","link":"https:\/\/www.logicbus.com.mx\/blog\/como-conectar-una-hmi-y-un-plc-fatek\/","title":{"rendered":"C\u00f3mo Conectar una HMI y un PLC Fatek"},"content":{"rendered":"<h3><b>C\u00f3mo Conectar una HMI y un PLC <a href=\"https:\/\/www.logicbus.com.mx\/fatek.php\">Fatek<\/a><\/b><\/h3>\n<p align=\"justify\"><span style=\"font-weight: 400;\">Para realizar la conexi\u00f3n entre un PLC de las Series <\/span><a href=\"https:\/\/tienda.logicbus.com.mx\/PLC-expandibles-serie-FBS_c_2807.html\"><span style=\"font-weight: 400;\">FBs<\/span><\/a><span style=\"font-weight: 400;\">, <\/span><a href=\"https:\/\/tienda.logicbus.com.mx\/PLC-Serie-HB1_c_2809.html\"><span style=\"font-weight: 400;\">HB1<\/span><\/a><span style=\"font-weight: 400;\"> y <\/span><a href=\"https:\/\/tienda.logicbus.com.mx\/PLC-Serie-B1-B1z_c_2853.html\"><span style=\"font-weight: 400;\">B1-B1z<\/span><\/a><span style=\"font-weight: 400;\"> con una <\/span><a href=\"https:\/\/tienda.logicbus.com.mx\/HMI-de-Pantalla-T%C3%A1ctil_c_1230.html\"><span style=\"font-weight: 400;\">HMI<\/span><\/a><span style=\"font-weight: 400;\"> de la Serie P (ya sea P2 o P5) de <a href=\"https:\/\/www.logicbus.com.mx\/fatek.php\">Fatek<\/a> primero hay definir la interfaz que vamos a utilizar, esta puede ser Ethernet o Serial<\/span><\/p>\n<h3><b>Serial RS-232<\/b><\/h3>\n<p align=\"justify\"><span style=\"font-weight: 400;\">En cuanto a interfaz Serial, los PLCs de <a href=\"https:\/\/www.logicbus.com.mx\/fatek.php\">Fatek<\/a> por default cuentan con un puerto RS-232 en el COM0 en cualquiera de los modelos de las Series FBs, B1, B1z y <a href=\"https:\/\/tienda.logicbus.com.mx\/PLC-Serie-HB1_c_2809.html\">HB1<\/a>, los PLCs modelo B1z adem\u00e1s de contar con este puerto RS-232 tambi\u00e9n cuentan con un puerto RS-485 ya integrado y los modelos <a href=\"https:\/\/tienda.logicbus.com.mx\/PLC-Serie-HB1_c_2809.html\">HB1<\/a> adicional cuentan con un puerto espacial trasero para conectar con las <a href=\"https:\/\/tienda.logicbus.com.mx\/HMI-de-Pantalla-T%C3%A1ctil_c_1230.html\">HMI<\/a> de la Serie P de <a href=\"https:\/\/www.logicbus.com.mx\/fatek.php\">Fatek<\/a> sin necesidad de cable<\/span><\/p>\n<figure id=\"attachment_38222\" aria-describedby=\"caption-attachment-38222\" style=\"width: 688px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.logicbus.com.mx\/fatek.php\"><img decoding=\"async\" class=\" wp-image-38222\" src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/08\/1-300x109.jpg\" alt=\"HMI A PLC\" width=\"688\" height=\"250\" srcset=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/08\/1-300x109.jpg 300w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/08\/1-150x55.jpg 150w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/08\/1.jpg 593w\" sizes=\"(max-width: 688px) 100vw, 688px\" \/><\/a><figcaption id=\"caption-attachment-38222\" class=\"wp-caption-text\">HMI A PLC<\/figcaption><\/figure>\n<p align=\"justify\"><span style=\"font-weight: 400;\">Para conectar desde el COM0 de cualquier PLC a cualquier HMI de <a href=\"https:\/\/www.logicbus.com.mx\/fatek.php\">Fatek<\/a> es recomendable usar el cable <\/span><a href=\"https:\/\/tienda.logicbus.com.mx\/FBS-232P0-9F-150_p_3187.html\"><span style=\"font-weight: 400;\">FBS-232P0-9F-150<\/span><\/a><span style=\"font-weight: 400;\"> o si se planea fabricar el cable se debe considerar el siguiente pinout:<\/span><\/p>\n<figure id=\"attachment_38221\" aria-describedby=\"caption-attachment-38221\" style=\"width: 634px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/www.logicbus.com.mx\/fatek.php\"><img decoding=\"async\" class=\"wp-image-38221\" src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/08\/2-300x136.jpg\" alt=\"Mini-DIN\" width=\"634\" height=\"287\" srcset=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/08\/2-300x136.jpg 300w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/08\/2-150x68.jpg 150w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/08\/2-20x10.jpg 20w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/08\/2.jpg 569w\" sizes=\"(max-width: 634px) 100vw, 634px\" \/><\/a><figcaption id=\"caption-attachment-38221\" class=\"wp-caption-text\">Mini-DIN<\/figcaption><\/figure>\n<h3><b>Serial RS-485<\/b><\/h3>\n<p align=\"justify\"><span style=\"font-weight: 400;\">Ahora bien, dado que a los <\/span><a href=\"https:\/\/tienda.logicbus.com.mx\/Fatek_c_3791.html\"><span style=\"font-weight: 400;\">PLCs<\/span><\/a><span style=\"font-weight: 400;\"> de <a href=\"https:\/\/www.logicbus.com.mx\/fatek.php\">Fatek<\/a> se les puede agregar puertos de comunicaci\u00f3n con m\u00f3dulos y\/o tarjetas de expansi\u00f3n, para el caso de puertos RS-232 vienen en un DB9 Macho al igual que los puertos seriales en las <\/span><a href=\"https:\/\/tienda.logicbus.com.mx\/pantallas-hmi.html\"><span style=\"font-weight: 400;\">HMIs<\/span><\/a><span style=\"font-weight: 400;\">, para ese caso es posible ocupar un cable Serial con terminales DB9 Macho-Hembra seg\u00fan el siguiente pinout:<\/span><\/p>\n<figure id=\"attachment_38220\" aria-describedby=\"caption-attachment-38220\" style=\"width: 604px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" class=\" wp-image-38220\" src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/08\/3-300x129.jpg\" alt=\"RS232\" width=\"604\" height=\"260\" srcset=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/08\/3-300x129.jpg 300w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/08\/3-150x65.jpg 150w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/08\/3-20x10.jpg 20w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/08\/3.jpg 597w\" sizes=\"(max-width: 604px) 100vw, 604px\" \/><figcaption id=\"caption-attachment-38220\" class=\"wp-caption-text\">RS232<\/figcaption><\/figure>\n<p align=\"justify\"><span style=\"font-weight: 400;\">Siguiendo la l\u00ednea de las Interfaces Serie, a los PLCs de <a href=\"https:\/\/www.logicbus.com.mx\/fatek.php\">Fatek<\/a> tambi\u00e9n se les pueden agregar puertos RS-485 (o incluso ya traerlos como vimos en el caso de los modelos B1z), para este caso se debe revisar la hoja de datos de la HMI que se tenga para ver cuales son los pines que corresponden a Data- (D-) y Data+(D+), mientras que para los PLCs estos puertos vienen se\u00f1alados como tal como se puede ver en imagen a continuaci\u00f3n:<\/span><\/p>\n<p><img decoding=\"async\" class=\"wp-image-38219 aligncenter\" src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/08\/4.jpg\" alt=\"\" width=\"281\" height=\"188\" srcset=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/08\/4.jpg 136w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/08\/4-18x13.jpg 18w\" sizes=\"(max-width: 281px) 100vw, 281px\" \/><\/p>\n<p align=\"justify\"><span style=\"font-weight: 400;\">Una vez ubicados los pines D+ y D- en la <a href=\"https:\/\/tienda.logicbus.com.mx\/HMI-de-Pantalla-T%C3%A1ctil_c_1230.html\">HMI<\/a> y PLC solo hay que conectarlos entre iguales.<\/span><\/p>\n<h3><b>Ethernet<\/b><\/h3>\n<p align=\"justify\"><span style=\"font-weight: 400;\">Si se planea realizar la conexi\u00f3n entre la <a href=\"https:\/\/tienda.logicbus.com.mx\/HMI-de-Pantalla-T%C3%A1ctil_c_1230.html\">HMI<\/a> y el PLC por ethernet lo m\u00e1s importante a considerar es contar con una HMI con puerto ethernet, estas <a href=\"https:\/\/tienda.logicbus.com.mx\/HMI-de-Pantalla-T%C3%A1ctil_c_1230.html\">HMIs<\/a> llevan una letra\u00a0 <\/span><b>\u201cN\u201d <\/b>\u00a0en su n\u00famero parte por ejemplo la <span style=\"font-weight: 400;\">P2070<\/span><b>N<\/b><span style=\"font-weight: 400;\">K<\/span><span style=\"font-weight: 400;\">, del lado del PLC se le debe de igual forma \u00edntegra el puerto ethernet por medio de una tarjeta de expansi\u00f3n, para la Serie <a href=\"https:\/\/tienda.logicbus.com.mx\/PLC-expandibles-serie-FBS_c_2807.html\">FBs<\/a> la m\u00e1s recomendada es la <a href=\"https:\/\/tienda.logicbus.com.mx\/PLC-expandibles-serie-FBS_c_2807.html\">FBs-CBES<\/a>, para realizar las conexiones basta con conectar directo con un cable LAN o por medio de un Router, Modem o Switch ethernet en caso de querer conectar m\u00e1s equipos o dependiendo si se necesita acceso a internet.<\/span><\/p>\n<ul>\n<li><em><span style=\"font-weight: 400;\">Conexi\u00f3n directa entre <a href=\"https:\/\/tienda.logicbus.com.mx\/HMI-de-Pantalla-T%C3%A1ctil_c_1230.html\">HMI<\/a> y PLC a trav\u00e9s de Ethernet<\/span><\/em><\/li>\n<\/ul>\n<figure id=\"attachment_38218\" aria-describedby=\"caption-attachment-38218\" style=\"width: 628px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" class=\" wp-image-38218\" src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/08\/5-300x84.jpg\" alt=\"HMI A PLC\" width=\"628\" height=\"176\" srcset=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/08\/5-300x84.jpg 300w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/08\/5-150x42.jpg 150w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/08\/5.jpg 606w\" sizes=\"(max-width: 628px) 100vw, 628px\" \/><figcaption id=\"caption-attachment-38218\" class=\"wp-caption-text\">HMI A PLC<\/figcaption><\/figure>\n<ul>\n<li><em><span style=\"font-weight: 400;\">Conexi\u00f3n entre <a href=\"https:\/\/tienda.logicbus.com.mx\/HMI-de-Pantalla-T%C3%A1ctil_c_1230.html\">HMI<\/a> y PLC a trav\u00e9s de ethernet con conmutador ethernet intermediario<\/span><\/em><\/li>\n<\/ul>\n<figure id=\"attachment_38217\" aria-describedby=\"caption-attachment-38217\" style=\"width: 641px\" class=\"wp-caption aligncenter\"><img decoding=\"async\" class=\" wp-image-38217\" src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/08\/6-300x58.jpg\" alt=\"HMI A PLC\" width=\"641\" height=\"124\" srcset=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/08\/6-300x58.jpg 300w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/08\/6-150x29.jpg 150w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/08\/6-600x116.jpg 600w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/08\/6.jpg 603w\" sizes=\"(max-width: 641px) 100vw, 641px\" \/><figcaption id=\"caption-attachment-38217\" class=\"wp-caption-text\">HMI A PLC<\/figcaption><\/figure>\n<p>&nbsp;<\/p>\n<h3 style=\"text-align: center;\">Cont\u00e1ctanos<\/h3>\n<hr \/>\n<p style=\"text-align: center;\"><img decoding=\"async\" class=\"alignnone wp-image-37978\" src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/06\/email-de-ventas-300x300.png\" alt=\"contacto para la empresa via email\" width=\"132\" height=\"132\" srcset=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/06\/email-de-ventas-300x300.png 300w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/06\/email-de-ventas-150x150.png 150w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/06\/email-de-ventas-180x180.png 180w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/06\/email-de-ventas-400x400.png 400w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/06\/email-de-ventas-18x18.png 18w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/06\/email-de-ventas-24x24.png 24w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/06\/email-de-ventas-48x48.png 48w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/06\/email-de-ventas-96x96.png 96w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/06\/email-de-ventas.png 500w\" sizes=\"(max-width: 132px) 100vw, 132px\" \/>\u00a0 \u00a0 \u00a0 <img decoding=\"async\" class=\"alignnone wp-image-37979\" src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/06\/email-de-soporte-300x300.png\" alt=\"contacto a la empresa via email de soporte\" width=\"130\" height=\"130\" srcset=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/06\/email-de-soporte-300x300.png 300w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/06\/email-de-soporte-150x150.png 150w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/06\/email-de-soporte-180x180.png 180w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/06\/email-de-soporte-400x400.png 400w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/06\/email-de-soporte-18x18.png 18w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/06\/email-de-soporte-24x24.png 24w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/06\/email-de-soporte-48x48.png 48w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/06\/email-de-soporte-96x96.png 96w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/06\/email-de-soporte.png 500w\" sizes=\"(max-width: 130px) 100vw, 130px\" \/>\u00a0 \u00a0 \u00a0 <img decoding=\"async\" class=\"alignnone wp-image-37980\" src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/06\/whatsapp-empresa-300x300.png\" alt=\"contacto con la empresa via red social\" width=\"128\" height=\"128\" srcset=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/06\/whatsapp-empresa-300x300.png 300w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/06\/whatsapp-empresa-150x150.png 150w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/06\/whatsapp-empresa-180x180.png 180w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/06\/whatsapp-empresa-400x400.png 400w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/06\/whatsapp-empresa-18x18.png 18w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/06\/whatsapp-empresa-24x24.png 24w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/06\/whatsapp-empresa-48x48.png 48w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/06\/whatsapp-empresa-96x96.png 96w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/06\/whatsapp-empresa.png 500w\" sizes=\"(max-width: 128px) 100vw, 128px\" \/>\u00a0 \u00a0 \u00a0 <img decoding=\"async\" class=\"alignnone wp-image-37981\" src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/06\/chat-online-300x300.png\" alt=\"contacto con la empresa via chat online\" width=\"126\" height=\"126\" srcset=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/06\/chat-online-300x300.png 300w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/06\/chat-online-150x150.png 150w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/06\/chat-online-180x180.png 180w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/06\/chat-online-400x400.png 400w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/06\/chat-online-18x18.png 18w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/06\/chat-online-24x24.png 24w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/06\/chat-online-48x48.png 48w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/06\/chat-online-96x96.png 96w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/06\/chat-online.png 500w\" sizes=\"(max-width: 126px) 100vw, 126px\" \/><\/p>\n<p style=\"text-align: center;\"><a href=\"mailto:ventas@logicbus.com\">ventas@logicbus.com<\/a>\u00a0 \u00a0 \u00a0 |\u00a0 \u00a0 \u00a0\u00a0<a href=\"mailto:soporte@logicbus.com\">soporte@logicbus.com<\/a>\u00a0 \u00a0 \u00a0 |\u00a0 \u00a0 \u00a0\u00a0<a href=\"https:\/\/api.whatsapp.com\/send?phone=525554316718&amp;text=Hola%20Logicbus,me%20gustar%C3%ADa%20solicitar%20informaci%C3%B3n\">55-5431-67-18<\/a>\u00a0 \u00a0 |\u00a0 \u00a0 \u00a0\u00a0<a href=\"https:\/\/tawk.to\/chat\/5ca674ff1de11b6e3b06f73d\/default\">Iniciar conversaci\u00f3n<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>C\u00f3mo Conectar una HMI y un PLC Fatek Para realizar la conexi\u00f3n entre un PLC de las Series FBs, HB1 y B1-B1z con una HMI de la Serie P (ya sea P2 o P5) de Fatek primero hay definir la interfaz que vamos a utilizar, esta puede ser Ethernet o Serial Serial RS-232 En cuanto [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":38222,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[71,5767],"tags":[48,5738,5736,5731,5735,14,5647,15,5646,20,5732,5733,5734],"class_list":["post-38216","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articulos","category-plcs-y-convertidores-de-protocolo","tag-automatizacion","tag-comunicacion","tag-comunicaciones-industriales","tag-fvdesigner","tag-fvrt","tag-hmi","tag-industrial","tag-plc","tag-protocolos","tag-scada","tag-serie-fbs","tag-serie-p2","tag-serie-p5"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.1 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>C\u00f3mo Conectar una HMI y un PLC Fatek &#8211; Blog Logicbus<\/title>\n<meta name=\"description\" content=\"Para realizar la conexi\u00f3n entre un PLC con una HMI de Fatek primero hay definir la interfaz que vamos a utilizar, esta puede ser Ethernet o...\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.logicbus.com.mx\/blog\/como-conectar-una-hmi-y-un-plc-fatek\/\" \/>\n<meta property=\"og:locale\" content=\"es_MX\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"C\u00f3mo Conectar una HMI y un PLC Fatek &#8211; Blog Logicbus\" \/>\n<meta property=\"og:description\" content=\"Para realizar la conexi\u00f3n entre un PLC con una HMI de Fatek primero hay definir la interfaz que vamos a utilizar, esta puede ser Ethernet o...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.logicbus.com.mx\/blog\/como-conectar-una-hmi-y-un-plc-fatek\/\" \/>\n<meta property=\"og:site_name\" content=\"Blog Logicbus\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/logicbus\/\" \/>\n<meta property=\"article:published_time\" content=\"2021-07-29T16:24:10+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-09-27T15:42:20+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/08\/1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"593\" \/>\n\t<meta property=\"og:image:height\" content=\"216\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Josue Cetina\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"Josue Cetina\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutos\" \/>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"C\u00f3mo Conectar una HMI y un PLC Fatek &#8211; Blog Logicbus","description":"Para realizar la conexi\u00f3n entre un PLC con una HMI de Fatek primero hay definir la interfaz que vamos a utilizar, esta puede ser Ethernet o...","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.logicbus.com.mx\/blog\/como-conectar-una-hmi-y-un-plc-fatek\/","og_locale":"es_MX","og_type":"article","og_title":"C\u00f3mo Conectar una HMI y un PLC Fatek &#8211; Blog Logicbus","og_description":"Para realizar la conexi\u00f3n entre un PLC con una HMI de Fatek primero hay definir la interfaz que vamos a utilizar, esta puede ser Ethernet o...","og_url":"https:\/\/www.logicbus.com.mx\/blog\/como-conectar-una-hmi-y-un-plc-fatek\/","og_site_name":"Blog Logicbus","article_publisher":"https:\/\/www.facebook.com\/logicbus\/","article_published_time":"2021-07-29T16:24:10+00:00","article_modified_time":"2022-09-27T15:42:20+00:00","og_image":[{"width":593,"height":216,"url":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/08\/1.jpg","type":"image\/jpeg"}],"author":"Josue Cetina","twitter_misc":{"Escrito por":"Josue Cetina","Tiempo de lectura":"3 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.logicbus.com.mx\/blog\/como-conectar-una-hmi-y-un-plc-fatek\/#article","isPartOf":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/como-conectar-una-hmi-y-un-plc-fatek\/"},"author":{"name":"Josue Cetina","@id":"https:\/\/www.logicbus.com.mx\/blog\/#\/schema\/person\/d2f308e65be01c1b9ab007719614b6a7"},"headline":"C\u00f3mo Conectar una HMI y un PLC Fatek","datePublished":"2021-07-29T16:24:10+00:00","dateModified":"2022-09-27T15:42:20+00:00","mainEntityOfPage":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/como-conectar-una-hmi-y-un-plc-fatek\/"},"wordCount":559,"commentCount":0,"publisher":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/#organization"},"image":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/como-conectar-una-hmi-y-un-plc-fatek\/#primaryimage"},"thumbnailUrl":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/08\/1.jpg","keywords":["automatizaci\u00f3n","comunicacion","Comunicaciones Industriales","FvDesigner","FvRT","hmi","industrial","PLC","protocolos","scada","Serie FBs","Serie P2","Serie P5"],"articleSection":["Articulos","PLCs y Convertidores de protocolo"],"inLanguage":"es","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.logicbus.com.mx\/blog\/como-conectar-una-hmi-y-un-plc-fatek\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.logicbus.com.mx\/blog\/como-conectar-una-hmi-y-un-plc-fatek\/","url":"https:\/\/www.logicbus.com.mx\/blog\/como-conectar-una-hmi-y-un-plc-fatek\/","name":"C\u00f3mo Conectar una HMI y un PLC Fatek &#8211; Blog Logicbus","isPartOf":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/como-conectar-una-hmi-y-un-plc-fatek\/#primaryimage"},"image":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/como-conectar-una-hmi-y-un-plc-fatek\/#primaryimage"},"thumbnailUrl":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/08\/1.jpg","datePublished":"2021-07-29T16:24:10+00:00","dateModified":"2022-09-27T15:42:20+00:00","description":"Para realizar la conexi\u00f3n entre un PLC con una HMI de Fatek primero hay definir la interfaz que vamos a utilizar, esta puede ser Ethernet o...","breadcrumb":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/como-conectar-una-hmi-y-un-plc-fatek\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.logicbus.com.mx\/blog\/como-conectar-una-hmi-y-un-plc-fatek\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.logicbus.com.mx\/blog\/como-conectar-una-hmi-y-un-plc-fatek\/#primaryimage","url":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/08\/1.jpg","contentUrl":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/08\/1.jpg","width":593,"height":216,"caption":"HMI A PLC"},{"@type":"BreadcrumbList","@id":"https:\/\/www.logicbus.com.mx\/blog\/como-conectar-una-hmi-y-un-plc-fatek\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Inicio","item":"https:\/\/www.logicbus.com.mx\/blog\/"},{"@type":"ListItem","position":2,"name":"C\u00f3mo Conectar una HMI y un PLC Fatek"}]},{"@type":"WebSite","@id":"https:\/\/www.logicbus.com.mx\/blog\/#website","url":"https:\/\/www.logicbus.com.mx\/blog\/","name":"Blog Logicbus","description":"Logicbus Blog ofrece informaci\u00f3n detallada sobre el control de procesos, sus tipos, elementos e importancia.","publisher":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.logicbus.com.mx\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/www.logicbus.com.mx\/blog\/#organization","name":"Logicbus Blog","url":"https:\/\/www.logicbus.com.mx\/blog\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.logicbus.com.mx\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/logo-logicbus-blog.png","contentUrl":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/logo-logicbus-blog.png","width":1761,"height":546,"caption":"Logicbus Blog"},"image":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/logicbus\/","https:\/\/x.com\/Logicbus"]},{"@type":"Person","@id":"https:\/\/www.logicbus.com.mx\/blog\/#\/schema\/person\/d2f308e65be01c1b9ab007719614b6a7","name":"Josue Cetina","image":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/JosueCetina-96x96.png","url":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/JosueCetina-96x96.png","contentUrl":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/JosueCetina-96x96.png","caption":"Josue Cetina"},"url":"https:\/\/www.logicbus.com.mx\/blog\/author\/josue-cetina\/"}]}},"_links":{"self":[{"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/posts\/38216","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/comments?post=38216"}],"version-history":[{"count":0,"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/posts\/38216\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/media\/38222"}],"wp:attachment":[{"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/media?parent=38216"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/categories?post=38216"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/tags?post=38216"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}