{"id":39862,"date":"2022-05-03T22:30:43","date_gmt":"2022-05-03T22:30:43","guid":{"rendered":"https:\/\/www.logicbus.com.mx\/blog\/?p=39862"},"modified":"2023-08-23T22:49:33","modified_gmt":"2023-08-23T22:49:33","slug":"como-comunicar-una-hmi-fatek-con-un-plc-de-la-misma-marca","status":"publish","type":"post","link":"https:\/\/www.logicbus.com.mx\/blog\/como-comunicar-una-hmi-fatek-con-un-plc-de-la-misma-marca\/","title":{"rendered":"\u00bfC\u00f3mo comunicar una HMI Fatek de la Serie P2 o P5 con un PLC ?"},"content":{"rendered":"<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Si vas a comunicar una <\/span><a href=\"https:\/\/www.logicbus.com.mx\/hmi-con-touchscreen.php\"><span style=\"font-weight: 400;\">HMI<\/span><\/a><span style=\"font-weight: 400;\"> de la <\/span><a href=\"https:\/\/tienda.logicbus.com.mx\/HMI-de-Pantalla-T%C3%A1ctil_c_1230.html\"><span style=\"font-weight: 400;\">Serie P2<\/span><\/a><span style=\"font-weight: 400;\"> o P5 de <a href=\"https:\/\/tienda.logicbus.com.mx\/Fatek_bymfg_17-7-1.html\">Fatek<\/a> con un PLC de cualquiera de las marcas que esta soporta, tenemos un <a href=\"https:\/\/www.logicbus.com.mx\/blog\/plcs-drivers-y-comunicaciones-que-soportan-las-hmis-de-fatek\/\">art\u00edculo con la lista de Drivers que soporta <\/a><\/span><span style=\"font-weight: 400;\">lo primero que necesitar\u00e1s ser\u00e1 la \u00faltima versi\u00f3n de <a href=\"https:\/\/tienda.logicbus.com.mx\/scada.html\">FvDesigner<\/a> que es el software de desarrollo para todas las <a href=\"https:\/\/tienda.logicbus.com.mx\/Fatek_bymfg_17-7-1.html\">HMIs de Fatek.<\/a><\/span><\/p>\n<p style=\"text-align: justify;\"><strong>Notas: <\/strong><span style=\"font-weight: 400;\">Para descargar la versi\u00f3n m\u00e1s reciente puedes consultar a nuestro equipos de Soporte T\u00e9cnico v\u00eda correo: <\/span><a href=\"mailto:soporte@logicbus.com\"><span style=\"font-weight: 400;\">soporte@logicbus.com<\/span><\/a><span style=\"font-weight: 400;\"> ellos te facilitaran un link de descarga sin costo alguno e incluso un peque\u00f1o proyecto Demo.<\/span><\/p>\n<p style=\"text-align: justify;\"><a href=\"https:\/\/www.logicbus.com.mx\/fatek.php\"><span style=\"font-weight: 400;\">Fatek<\/span><\/a><span style=\"font-weight: 400;\"> est\u00e1 constantemente desarrollando nuevos equipos, por lo que si tu HMI no se encuentra en la versi\u00f3n que tienes instalada seguramente ya habr\u00e1 una nueva versi\u00f3n, favor de consultar con soporte t\u00e9cnico.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Una vez instalado <\/span><a href=\"https:\/\/www.logicbus.com.mx\/FvDesigner.php\"><span style=\"font-weight: 400;\">FvDesigner<\/span><\/a><span style=\"font-weight: 400;\">, con un proyecto creado y abierto, habr\u00e1 que definir el medio f\u00edsico por donde se conectara, puedes consultar el siguiente art\u00edculo sobre ello:<\/span><\/p>\n<p style=\"text-align: justify;\"><a href=\"https:\/\/www.logicbus.com.mx\/blog\/como-conectar-una-hmi-y-un-plc-fatek\/\"><span style=\"font-weight: 400;\">https:\/\/www.logicbus.com.mx\/blog\/como-conectar-una-hmi-y-un-plc-fatek\/<\/span><\/a><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">En FvDesigner para crear una nueva comunicaci\u00f3n o enlace, hay que ir <strong>\u201cProject Explorer\u201d &#8211; \u201cSystem\u201d &#8211; \u201cLink\u201d<\/strong>; Como se muestra en la siguiente imagen, se debe dar click izquierdo sobre \u201cLink\u201d.<\/span><\/p>\n<p style=\"text-align: justify;\"><img decoding=\"async\" class=\"aligncenter wp-image-39864 size-full\" src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/05\/1.png\" alt=\"\" width=\"700\" height=\"700\" srcset=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/05\/1.png 700w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/05\/1-300x300.png 300w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/05\/1-150x150.png 150w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/05\/1-24x24.png 24w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/05\/1-48x48.png 48w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/05\/1-96x96.png 96w\" sizes=\"(max-width: 700px) 100vw, 700px\" \/><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Con esta acci\u00f3n se desplegar\u00e1 una ventana llamada <strong>\u201cLink\u201d<\/strong> como la que se muestra a continuaci\u00f3n, se debe dar click en el bot\u00f3n <strong>\u201cAdd\u201d<\/strong> para agregar una nueva comunicaci\u00f3n, tambi\u00e9n est\u00e1n las opciones de los botones <strong>\u201cDelete\u201d<\/strong> para borrar una comunicaci\u00f3n ya creada y <strong>\u201cEdit\u201d<\/strong> para modificar la configuraci\u00f3n de una comunicaci\u00f3n ya creada.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Al dar click en \u201c<strong>Add<\/strong>\u201d se desplegar\u00e1 la siguiente sub ventana:<img decoding=\"async\" class=\"aligncenter wp-image-39865 size-full\" src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/05\/unnamed-1.png\" alt=\"\" width=\"602\" height=\"600\" srcset=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/05\/unnamed-1.png 602w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/05\/unnamed-1-300x300.png 300w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/05\/unnamed-1-150x150.png 150w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/05\/unnamed-1-24x24.png 24w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/05\/unnamed-1-48x48.png 48w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/05\/unnamed-1-96x96.png 96w\" sizes=\"(max-width: 602px) 100vw, 602px\" \/><\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">en esta hemos indicado con n\u00fameros algunas partes importantes de explicar<\/span><\/p>\n<p style=\"text-align: justify;\"><img decoding=\"async\" class=\"aligncenter wp-image-39866 size-full\" src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/05\/unnamed-2.png\" alt=\"\" width=\"798\" height=\"714\" srcset=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/05\/unnamed-2.png 798w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/05\/unnamed-2-300x268.png 300w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/05\/unnamed-2-150x134.png 150w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/05\/unnamed-2-768x687.png 768w\" sizes=\"(max-width: 798px) 100vw, 798px\" \/><\/p>\n<ol>\n<li style=\"text-align: justify;\"><span style=\"font-weight: 400;\">[Name] este solo es un nombre que se mostrar\u00e1 en <strong>\u201cLink\u201d<\/strong> y que le podemos dar para recordar una configuraci\u00f3n espec\u00edfica<\/span><\/li>\n<li style=\"text-align: justify;\"><span style=\"font-weight: 400;\">[Interface Type] Esta es la interfaz que se usar\u00e1 para conectar con la HMI, las principales son serial y Ethernet<\/span><\/li>\n<li style=\"text-align: justify;\"><span style=\"font-weight: 400;\">[Manufacturer] se debe de indicar quien es el fabricante del PLC y las alternativas depende si se seleccion\u00f3 ethernet<\/span><\/li>\n<li style=\"text-align: justify;\"><span style=\"font-weight: 400;\">[Product Series] aqu\u00ed se indica la serie o modelo de PLC que se usar\u00e1 las alternativas mostradas dependen del fabricante seleccionado<\/span><\/li>\n<li style=\"text-align: justify;\"><span style=\"font-weight: 400;\">[Interface Setting] es aqu\u00ed en donde se configura la comunicaci\u00f3n que se usar\u00e1, y depende de las configuraciones en los puntos 1, 2, 3, y 4<\/span><\/li>\n<li style=\"text-align: justify;\"><span style=\"font-weight: 400;\">[Device Name] Este es un nombre con el que estaremos llamando la comunicaci\u00f3n creada, de preferencia debe ser un nombre corto y simb\u00f3lico porque lo estaremos usando con frecuencia<\/span><\/li>\n<\/ol>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">En este caso usaremos un PLC Fatek por medio de comunicaci\u00f3n Serial usando su mismo protocolo de comunicaci\u00f3n por lo que hemos dejado la comunicaci\u00f3n que viene por default y llamado y solo cambiado el <strong>\u201cDevice Name\u201d<\/strong> por PLC1.\u00a0<\/span><span style=\"font-weight: 400;\">Una vez hayamos terminado de configurar nuestra comunicaci\u00f3n, debemos dar click en <strong>\u201cOK\u201d,<\/strong> \u00a1Listo! Ahora estamos listos para empezar a usar nuestra comunicaci\u00f3n<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Por ejemplo si quisi\u00e9ramos ver el estado de una entrada digital de nuestro PLC Fatek, necesitamos ubicar en la parte superior derecha en la pesta\u00f1a <strong>\u201cDesign\u201d<\/strong> la secci\u00f3n <strong>\u201cObjects\u201d<\/strong>, ah\u00ed la primer figura que es como un foco es la <strong>\u201cLamp\u201d<\/strong> o indicador sencillo, basta con darle un click y luego dar un click en nuestro espacio de trabajo para agregar la l\u00e1mpara:<\/span><\/p>\n<p style=\"text-align: justify;\"><img decoding=\"async\" class=\"aligncenter wp-image-39867 size-full\" src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/05\/unnamed-3.png\" alt=\"\" width=\"297\" height=\"391\" srcset=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/05\/unnamed-3.png 297w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/05\/unnamed-3-228x300.png 228w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/05\/unnamed-3-114x150.png 114w\" sizes=\"(max-width: 297px) 100vw, 297px\" \/><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Otras alternativa es ir a la<strong> \u201cToolbox\u201d<\/strong>, esta por default est\u00e1 del lado derecho, en caso de que por alguna raz\u00f3n esta no te aparezca o no la encuentres puedes activarla y desactivarla en <strong>\u201cView\u201d<\/strong> -&gt; <strong>\u201cToolbox\u201d<\/strong>, ya con la Toolbox ubicada damos click en <strong>\u201cLamp\/Switch\u201d<\/strong>, ya con ese peque\u00f1o men\u00fa desplegado nuevamente la primer figura es la <strong>\u201cLamp\u201d<\/strong>, en este caso es necesario dar clic y arrastrar la figura al espacio de trabajo, sin embargo, el resultado es el mismo al del procedimiento anterior:<\/span><\/p>\n<p style=\"text-align: justify;\"><img decoding=\"async\" class=\"aligncenter wp-image-39868 size-full\" src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/05\/unnamed-4.png\" alt=\"\" width=\"344\" height=\"314\" srcset=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/05\/unnamed-4.png 344w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/05\/unnamed-4-300x274.png 300w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/05\/unnamed-4-150x137.png 150w\" sizes=\"(max-width: 344px) 100vw, 344px\" \/><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">\u00a1Bien! Ahora pasemos a donde nos quedamos respecto a la comunicaci\u00f3n, pr\u00e1cticamente con todos los <strong>\u201cObjects\u201d<\/strong> el procedimiento es el mismo, solo debemos dar doble click sobre el objeto ya en nuestro espacio de trabajo, esto desplegar\u00e1 una ventana\u00a0 de configuraci\u00f3n, debemos buscar el espacio en donde dice <strong>\u201cAddress\u201d<\/strong>, en un peque\u00f1o cuadro veremos una direcci\u00f3n que tiene definido ese objeto.<\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Inmediatamente despu\u00e9s hay un peque\u00f1o bot\u00f3n con <strong>\u201c&#8230;\u201d<\/strong> (tres puntos), aqu\u00ed es donde usaremos la comunicaci\u00f3n ya creada, dando click nos desplegar\u00e1 una peque\u00f1a subventana, en <strong>\u201cDevice\u201d<\/strong> debemos seleccionar nuestra comunicaci\u00f3n creada, en <strong>\u201cType\u201d<\/strong> y <strong>\u201cAddress\u201d<\/strong> normalmente cambia dependiendo la comunicaci\u00f3n, en este caso al ser un <a href=\"https:\/\/tienda.logicbus.com.mx\/Fatek_bymfg_17-7-1.html\">PLC Fatek<\/a>, las entradas digitales se representan con <strong>\u201cX\u201d<\/strong> y la primera entrad se referencia con el n\u00famero \u201c0\u201d, una vez definido esto ya solo basta con dar <strong>\u201cEnt\u201d<\/strong> y despu\u00e9s <strong>\u201cOK\u201d,<\/strong> listo ahora puedes probar tu comunicaci\u00f3n en el simulador o directamente con una <a href=\"https:\/\/tienda.logicbus.com.mx\/Fatek_bymfg_17-7-1.html\">HMI y un PLC<\/a>: <img decoding=\"async\" class=\"aligncenter wp-image-39869 size-full\" src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/05\/unnamed-5.png\" alt=\"\" width=\"919\" height=\"588\" srcset=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/05\/unnamed-5.png 919w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/05\/unnamed-5-300x192.png 300w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/05\/unnamed-5-150x96.png 150w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/05\/unnamed-5-768x491.png 768w\" sizes=\"(max-width: 919px) 100vw, 919px\" \/><\/span><\/p>\n<p style=\"text-align: justify;\"><span style=\"font-weight: 400;\">Ahora veamos un ejemplo de c\u00f3mo realizar la comunicaci\u00f3n Serie y Ethernet con un <a href=\"https:\/\/tienda.logicbus.com.mx\/Fatek_bymfg_17-7-1.html\">PLC Fatek<\/a> para ver algunas variables de tipo entera en el siguiente video:<br \/>\n<\/span><br \/>\n<iframe title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/OwPIfA7F-Ig\" width=\"560\" height=\"315\" frameborder=\"0\" allowfullscreen=\"allowfullscreen\"><\/iframe><\/p>\n<p><span style=\"font-size: 1.21429rem;\">Si usted est\u00e1 trabajando en cualquier aplicaci\u00f3n en la que le podamos ayudar o tiene alguna pregunta, por favor h\u00e1ganoslo saber. Ofrecemos soporte t\u00e9cnico gratuito para ayudarle a escoger el mejor equipo para su aplicaci\u00f3n.<\/span><\/p>\n<p><strong>Cont\u00e1ctanos:<\/strong><br \/>\n<strong>Email:<\/strong> <a href=\"mailto:ventas@logicbus.com\">ventas@logicbus.com<\/a> y <a href=\"mailto:soporte@logicbus.com\">soporte@logicbus.com<\/a><br \/>\n<strong>Whatsapp:<\/strong> <a href=\"https:\/\/api.whatsapp.com\/send?phone=525554316718&amp;text=Hola%20Logicbus,me%20gustar\u00eda%20solicitar%20informaci\u00f3n\">55-5431-6718<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Si vas a comunicar una HMI de la Serie P2 o P5 de Fatek con un PLC de cualquiera de las marcas que esta soporta, tenemos un art\u00edculo con la lista de Drivers que soporta lo primero que necesitar\u00e1s ser\u00e1 la \u00faltima versi\u00f3n de FvDesigner que es el software de desarrollo para todas las HMIs [&hellip;]<\/p>\n","protected":false},"author":4,"featured_media":39873,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[5534,71,5767],"tags":[5609,5560,5731,14,5647,15,5732,5733,5734,5635],"class_list":["post-39862","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-aplicaciones-de-automatizacion-en-la-industria","category-articulos","category-plcs-y-convertidores-de-protocolo","tag-automation","tag-fatek","tag-fvdesigner","tag-hmi","tag-industrial","tag-plc","tag-serie-fbs","tag-serie-p2","tag-serie-p5","tag-tutorial"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>\u00bfC\u00f3mo comunicar una HMI Fatek de la Serie P2 o P5 con un PLC ?<\/title>\n<meta name=\"description\" content=\"Si vas a comunicar una HMI de la Serie P2 o P5 de Fatek con un PLC de cualquiera de las marcas que esta soporta, tenemos un art\u00edculo con la lista de Drivers\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.logicbus.com.mx\/blog\/como-comunicar-una-hmi-fatek-con-un-plc-de-la-misma-marca\/\" \/>\n<meta property=\"og:locale\" content=\"es_MX\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"\u00bfC\u00f3mo comunicar una HMI Fatek de la Serie P2 o P5 con un PLC ?\" \/>\n<meta property=\"og:description\" content=\"Si vas a comunicar una HMI de la Serie P2 o P5 de Fatek con un PLC de cualquiera de las marcas que esta soporta, tenemos un art\u00edculo con la lista de Drivers\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.logicbus.com.mx\/blog\/como-comunicar-una-hmi-fatek-con-un-plc-de-la-misma-marca\/\" \/>\n<meta property=\"og:site_name\" content=\"Blog Logicbus\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/logicbus\/\" \/>\n<meta property=\"article:published_time\" content=\"2022-05-03T22:30:43+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-08-23T22:49:33+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/05\/v.png\" \/>\n\t<meta property=\"og:image:width\" content=\"801\" \/>\n\t<meta property=\"og:image:height\" content=\"400\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Josue Cetina\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"Josue Cetina\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutos\" \/>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"\u00bfC\u00f3mo comunicar una HMI Fatek de la Serie P2 o P5 con un PLC ?","description":"Si vas a comunicar una HMI de la Serie P2 o P5 de Fatek con un PLC de cualquiera de las marcas que esta soporta, tenemos un art\u00edculo con la lista de Drivers","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.logicbus.com.mx\/blog\/como-comunicar-una-hmi-fatek-con-un-plc-de-la-misma-marca\/","og_locale":"es_MX","og_type":"article","og_title":"\u00bfC\u00f3mo comunicar una HMI Fatek de la Serie P2 o P5 con un PLC ?","og_description":"Si vas a comunicar una HMI de la Serie P2 o P5 de Fatek con un PLC de cualquiera de las marcas que esta soporta, tenemos un art\u00edculo con la lista de Drivers","og_url":"https:\/\/www.logicbus.com.mx\/blog\/como-comunicar-una-hmi-fatek-con-un-plc-de-la-misma-marca\/","og_site_name":"Blog Logicbus","article_publisher":"https:\/\/www.facebook.com\/logicbus\/","article_published_time":"2022-05-03T22:30:43+00:00","article_modified_time":"2023-08-23T22:49:33+00:00","og_image":[{"width":801,"height":400,"url":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/05\/v.png","type":"image\/png"}],"author":"Josue Cetina","twitter_misc":{"Escrito por":"Josue Cetina","Tiempo de lectura":"5 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.logicbus.com.mx\/blog\/como-comunicar-una-hmi-fatek-con-un-plc-de-la-misma-marca\/#article","isPartOf":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/como-comunicar-una-hmi-fatek-con-un-plc-de-la-misma-marca\/"},"author":{"name":"Josue Cetina","@id":"https:\/\/www.logicbus.com.mx\/blog\/#\/schema\/person\/d2f308e65be01c1b9ab007719614b6a7"},"headline":"\u00bfC\u00f3mo comunicar una HMI Fatek de la Serie P2 o P5 con un PLC ?","datePublished":"2022-05-03T22:30:43+00:00","dateModified":"2023-08-23T22:49:33+00:00","mainEntityOfPage":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/como-comunicar-una-hmi-fatek-con-un-plc-de-la-misma-marca\/"},"wordCount":918,"commentCount":0,"publisher":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/#organization"},"image":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/como-comunicar-una-hmi-fatek-con-un-plc-de-la-misma-marca\/#primaryimage"},"thumbnailUrl":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/05\/v.png","keywords":["automation","FATEK","FvDesigner","hmi","industrial","PLC","Serie FBs","Serie P2","Serie P5","Tutorial"],"articleSection":["Aplicaciones","Articulos","PLCs y Convertidores de protocolo"],"inLanguage":"es","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.logicbus.com.mx\/blog\/como-comunicar-una-hmi-fatek-con-un-plc-de-la-misma-marca\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.logicbus.com.mx\/blog\/como-comunicar-una-hmi-fatek-con-un-plc-de-la-misma-marca\/","url":"https:\/\/www.logicbus.com.mx\/blog\/como-comunicar-una-hmi-fatek-con-un-plc-de-la-misma-marca\/","name":"\u00bfC\u00f3mo comunicar una HMI Fatek de la Serie P2 o P5 con un PLC ?","isPartOf":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/como-comunicar-una-hmi-fatek-con-un-plc-de-la-misma-marca\/#primaryimage"},"image":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/como-comunicar-una-hmi-fatek-con-un-plc-de-la-misma-marca\/#primaryimage"},"thumbnailUrl":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/05\/v.png","datePublished":"2022-05-03T22:30:43+00:00","dateModified":"2023-08-23T22:49:33+00:00","description":"Si vas a comunicar una HMI de la Serie P2 o P5 de Fatek con un PLC de cualquiera de las marcas que esta soporta, tenemos un art\u00edculo con la lista de Drivers","breadcrumb":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/como-comunicar-una-hmi-fatek-con-un-plc-de-la-misma-marca\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.logicbus.com.mx\/blog\/como-comunicar-una-hmi-fatek-con-un-plc-de-la-misma-marca\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.logicbus.com.mx\/blog\/como-comunicar-una-hmi-fatek-con-un-plc-de-la-misma-marca\/#primaryimage","url":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/05\/v.png","contentUrl":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/05\/v.png","width":801,"height":400},{"@type":"BreadcrumbList","@id":"https:\/\/www.logicbus.com.mx\/blog\/como-comunicar-una-hmi-fatek-con-un-plc-de-la-misma-marca\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Inicio","item":"https:\/\/www.logicbus.com.mx\/blog\/"},{"@type":"ListItem","position":2,"name":"\u00bfC\u00f3mo comunicar una HMI Fatek de la Serie P2 o P5 con un PLC ?"}]},{"@type":"WebSite","@id":"https:\/\/www.logicbus.com.mx\/blog\/#website","url":"https:\/\/www.logicbus.com.mx\/blog\/","name":"Blog Logicbus","description":"Logicbus Blog ofrece informaci\u00f3n detallada sobre el control de procesos, sus tipos, elementos e importancia.","publisher":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.logicbus.com.mx\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/www.logicbus.com.mx\/blog\/#organization","name":"Logicbus Blog","url":"https:\/\/www.logicbus.com.mx\/blog\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.logicbus.com.mx\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/logo-logicbus-blog.png","contentUrl":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/logo-logicbus-blog.png","width":1761,"height":546,"caption":"Logicbus Blog"},"image":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/logicbus\/","https:\/\/x.com\/Logicbus"]},{"@type":"Person","@id":"https:\/\/www.logicbus.com.mx\/blog\/#\/schema\/person\/d2f308e65be01c1b9ab007719614b6a7","name":"Josue Cetina","image":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/JosueCetina-96x96.png","url":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/JosueCetina-96x96.png","contentUrl":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/JosueCetina-96x96.png","caption":"Josue Cetina"},"url":"https:\/\/www.logicbus.com.mx\/blog\/author\/josue-cetina\/"}]}},"_links":{"self":[{"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/posts\/39862","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/comments?post=39862"}],"version-history":[{"count":0,"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/posts\/39862\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/media\/39873"}],"wp:attachment":[{"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/media?parent=39862"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/categories?post=39862"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/tags?post=39862"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}