{"id":40938,"date":"2022-11-22T18:55:50","date_gmt":"2022-11-22T18:55:50","guid":{"rendered":"https:\/\/www.logicbus.com.mx\/blog\/?p=40938"},"modified":"2023-05-31T17:36:58","modified_gmt":"2023-05-31T17:36:58","slug":"tecnologias-plcs-vs-pacs-vs-ipcs","status":"publish","type":"post","link":"https:\/\/www.logicbus.com.mx\/blog\/tecnologias-plcs-vs-pacs-vs-ipcs\/","title":{"rendered":"Tecnolog\u00edas PLCs vs PACs vs IPCs"},"content":{"rendered":"<p align=\"justify\"><span style=\"font-weight: 400;\">En el mundo de la automatizaci\u00f3n industrial, los t\u00e9rminos <a href=\"https:\/\/www.logicbus.com.mx\/plc.php\"><strong>PLC, PAC e IPC<\/strong><\/a> se lanzan como si fueran intercambiables. El problema es que en muchos sentidos lo son. Y, a medida que avanzan las tecnolog\u00edas en las tres categor\u00edas de dispositivos, sus caracter\u00edsticas y beneficios \u00fanicos convergen y sus diferencias se vuelven menos notables.<\/span><\/p>\n<p align=\"justify\"><img decoding=\"async\" class=\"wp-image-40945 size-full aligncenter\" src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/11\/bbnn-6-1.png\" alt=\"\" width=\"800\" height=\"401\" srcset=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/11\/bbnn-6-1.png 800w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/11\/bbnn-6-1-300x150.png 300w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/11\/bbnn-6-1-150x75.png 150w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/11\/bbnn-6-1-768x385.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p align=\"justify\"><span style=\"font-weight: 400;\">Entonces, <em>\u00bfen qu\u00e9 se diferencian estas tres tecnolog\u00edas?<\/em><\/span><\/p>\n<h4><b>La evoluci\u00f3n de los controladores<\/b><\/h4>\n<p align=\"justify\"><span style=\"font-weight: 400;\">Hoy en d\u00eda, los <a href=\"https:\/\/www.logicbus.com.mx\/plc.php\"><strong>PLC<\/strong><\/a> automatizan los procesos, las funciones de la m\u00e1quina e incluso l\u00edneas de producci\u00f3n completas dentro de las plantas de fabricaci\u00f3n. <\/span><\/p>\n<p align=\"justify\"><span style=\"font-weight: 400;\">Proporcionan varias <strong>ventajas<\/strong> sobre los sistemas de automatizaci\u00f3n anteriores: <\/span><\/p>\n<ul>\n<li>\n<p align=\"justify\"><span style=\"font-weight: 400;\">Toleran el entorno industrial.<\/span><\/p>\n<\/li>\n<li>\n<p align=\"justify\"><span style=\"font-weight: 400;\">Son m\u00e1s fiables y m\u00e1s compactos.<\/span><\/p>\n<\/li>\n<li>\n<p align=\"justify\"><span style=\"font-weight: 400;\">Requieren menos mantenimiento que los sistemas de rel\u00e9s. <\/span><\/p>\n<\/li>\n<li>\n<p align=\"justify\"><span style=\"font-weight: 400;\">Utilizan un lenguaje de programaci\u00f3n simple y son f\u00e1cilmente extensibles con m\u00f3dulos de E\/S adicionales.<\/span><\/p>\n<\/li>\n<\/ul>\n<p align=\"justify\"><span style=\"font-weight: 400;\">A principios de la d\u00e9cada de 2000 se introdujeron los controladores de automatizaci\u00f3n de procesos <strong>(PAC).<\/strong> Se pueden describir como controladores industriales que <strong>combinan la funcionalidad de un <a href=\"https:\/\/www.logicbus.com.mx\/plc.php\">PLC<\/a> con la capacidad de procesamiento de una PC.<\/strong> Sin embargo, sin una definici\u00f3n est\u00e1ndar, la distinci\u00f3n entre PAC y <a href=\"https:\/\/www.logicbus.com.mx\/plc.php\">PLC<\/a> sigue siendo difusa.<\/span><\/p>\n<p align=\"justify\"><img decoding=\"async\" class=\"wp-image-40947 size-full aligncenter\" src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/11\/bbnn-7-1.png\" alt=\"\" width=\"800\" height=\"401\" srcset=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/11\/bbnn-7-1.png 800w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/11\/bbnn-7-1-300x150.png 300w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/11\/bbnn-7-1-150x75.png 150w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/11\/bbnn-7-1-768x385.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p align=\"justify\"><span style=\"font-weight: 400;\">Los <a href=\"https:\/\/www.logicbus.com.mx\/plc.php\">PLC<\/a> de gama alta incorporan muchos de los atributos que alguna vez fueron exclusivos de los PAC: lenguajes de programaci\u00f3n est\u00e1ndar, la capacidad de expandir la funcionalidad a trav\u00e9s de m\u00f3dulos adicionales, conectividad a varios sistemas de bus y monitoreo y control de una gran cantidad de E\/S.<\/span><\/p>\n<h4><b>Entonces, \u00bfCu\u00e1l es la diferencia?<\/b><\/h4>\n<p align=\"justify\"><span style=\"font-weight: 400;\">Desafortunadamente, las diferencias entre <a href=\"https:\/\/www.logicbus.com.mx\/plc.php\">PLC<\/a>, PAC e IPC siguen siendo tonos de gris en lugar de blanco y negro.<\/span><\/p>\n<p align=\"justify\"><span style=\"font-weight: 400;\">Dicho esto, la forma m\u00e1s sencilla de ver estos tres dispositivos es: un <a href=\"https:\/\/www.logicbus.com.mx\/plc.php\">PLC<\/a> puede considerarse como el controlador base est\u00e1ndar; el PAC es similar a un <a href=\"https:\/\/www.logicbus.com.mx\/plc.php\">PLC<\/a> pero con caracter\u00edsticas adicionales; y, el IPC ejecuta el mismo software que se encuentra en un PAC pero con todas las caracter\u00edsticas de una computadora personal.<\/span><\/p>\n<p><b>Echemos un vistazo m\u00e1s de cerca<\/b><\/p>\n<ul>\n<li>\n<h4><a href=\"https:\/\/www.logicbus.com.mx\/plc.php\"><b>Los PLC<\/b><\/a><\/h4>\n<p align=\"justify\"><span style=\"font-weight: 400;\">Tienen una huella peque\u00f1a y generalmente usan l\u00f3gica de escalera para controlar maquinaria o procesos discretos. <strong>Ofrecen una amplia gama de caracter\u00edsticas<\/strong>, desde E\/S anal\u00f3gicas hasta protocolos de comunicaci\u00f3n avanzados, y son relativamente baratos, lo que los convierte en la opci\u00f3n de referencia en <strong>proyectos a peque\u00f1a escala<\/strong>. Los <a href=\"https:\/\/www.logicbus.com.mx\/plc.php\">PLC<\/a> m\u00e1s avanzados son capaces de E\/S remotas y control de movimiento.<\/span><\/p>\n<\/li>\n<\/ul>\n<p><a href=\"https:\/\/www.logicbus.com.mx\/controllino.php\"><img decoding=\"async\" class=\"wp-image-40946 size-full aligncenter\" src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/11\/sas-1.png\" alt=\"\" width=\"657\" height=\"314\" srcset=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/11\/sas-1.png 657w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/11\/sas-1-300x143.png 300w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/11\/sas-1-150x72.png 150w\" sizes=\"(max-width: 657px) 100vw, 657px\" \/><\/a><\/p>\n<ul>\n<li>\n<h4><b>Los PAC<\/b><\/h4>\n<p align=\"justify\"><span style=\"font-weight: 400;\">Son m\u00e1s adecuados para soluciones de automatizaci\u00f3n m\u00e1s complejas que se ocupan del control avanzado de procesos, control de movimiento, visualizaci\u00f3n y m\u00e1s. Adem\u00e1s, los <strong>PAC<\/strong> utilizan la l\u00f3gica basada en excepciones en lugar de la basada en escaleras. Son m\u00e1s grandes y mucho m\u00e1s caros que los PLC, pero proporcionan una mayor escalabilidad, admiten una gran cantidad de E\/S de control, ofrecen la posibilidad de agregar otros PAC para redundancia y mucho m\u00e1s.<\/span><\/p>\n<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<ul>\n<li>\n<h4><b>Los IPC <\/b><\/h4>\n<p align=\"justify\"><strong>Ofrecen<\/strong><span style=\"font-weight: 400;\"> las mismas ventajas que ofrecen los PAC, pero con a\u00fan <strong>m\u00e1s capacidades<\/strong>. Cada vez son m\u00e1s adecuados para<strong> entornos industriales<\/strong> tanto en el lado del hardware (construcci\u00f3n m\u00e1s robusta) como en el lado del software (m\u00e1s aplicaciones).<\/span><\/p>\n<\/li>\n<\/ul>\n<p align=\"justify\">Los IPC se utilizan para cualquier cosa que necesite la potencia de la CPU y la versatilidad de los sistemas operativos como Windows o Linux. Algunos se utilizan como centro de control o centro de base de datos para otros dispositivos de control, como <a href=\"https:\/\/www.logicbus.com.mx\/plc.php\">PLC<\/a> y PAC.<\/p>\n<h4><b>\u00bfQu\u00e9 controlador es el adecuado para usted?<\/b><\/h4>\n<p><span style=\"font-weight: 400;\">La respuesta limpia y ordenada es: <strong>depende. <\/strong><\/span><\/p>\n<p align=\"justify\"><span style=\"font-weight: 400;\">Un profesional de la industria sugiri\u00f3: <\/span><b>&#8220;Si est\u00e1 buscando una m\u00e1quina independiente, un <a href=\"https:\/\/www.logicbus.com.mx\/plc.php\">PLC<\/a> puede ser la opci\u00f3n correcta. Pero si tambi\u00e9n desea abordar el movimiento y la seguridad o controlar las E\/S remotas, un PAC es a menudo el camino a seguir. Y si necesita agregar caracter\u00edsticas y software adicionales m\u00e1s all\u00e1 de lo que puede hacer un PAC, es cuando podr\u00eda comenzar a buscar un IPC &#8220;.<\/b><\/p>\n<p align=\"justify\"><span style=\"font-weight: 400;\">El precio siempre ser\u00e1 un determinante importante. Sin embargo, <em>\u00bfest\u00e1 hablando de costos iniciales o costos de por vida?<\/em> En algunos casos, una gran inversi\u00f3n inicial puede ser m\u00e1s barata a largo plazo cuando se consideran las necesidades futuras de escalabilidad y las capacidades anal\u00edticas y de miner\u00eda de datos para la mejora continua del proceso. <\/span><\/p>\n<p align=\"justify\"><span style=\"font-weight: 400;\">En \u00faltima instancia, la selecci\u00f3n final estar\u00e1 determinada por una variedad de factores que se aplican a su aplicaci\u00f3n espec\u00edfica, incluidos los requisitos funcionales.<\/span><\/p>\n<p align=\"justify\"><img decoding=\"async\" class=\"alignnone wp-image-40948 size-full\" src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/11\/bbnn-8-1.png\" alt=\"\" width=\"800\" height=\"401\" srcset=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/11\/bbnn-8-1.png 800w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/11\/bbnn-8-1-300x150.png 300w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/11\/bbnn-8-1-150x75.png 150w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/11\/bbnn-8-1-768x385.png 768w\" sizes=\"(max-width: 800px) 100vw, 800px\" \/><\/p>\n<p align=\"justify\"><span style=\"font-weight: 400;\">RTA se especializa en la fabricaci\u00f3n de productos de conectividad f\u00e1ciles de usar, incluyendo puertas de enlace de protocolo industrial, pilas de c\u00f3digo fuente integradas y soluciones OEM personalizadas. Nuestros productos son utilizados por ingenieros de control en f\u00e1bricas de todo el mundo y cuentan con el respaldo de nuestro soporte t\u00e9cnico Enginerd\u00ae l\u00edder en la industria para ayudar a ahorrar tiempo, dinero y molestias. <\/span><\/p>\n<p align=\"justify\"><span style=\"font-weight: 400;\">Adem\u00e1s cuentan con una garant\u00eda de 5 a\u00f1os, est\u00e1n hechos en Estados Unidos y siempre est\u00e1n en stock, listos para enviar el mismo d\u00eda que se realiza un pedido.<\/span><\/p>\n<h3 style=\"text-align: center;\">Cont\u00e1ctanos<\/h3>\n<div class=\"container-reviews\"><a href=\"https:\/\/tienda.logicbus.com.mx\/\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" class=\"card-review\" src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/11\/tienda.png \" width=\"102\" height=\"102\" \/><\/a><a href=\"https:\/\/www.logicbus.com.mx\/\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" class=\"card-review\" src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/11\/www.png \" width=\"104\" height=\"104\" \/><\/a><a href=\"https:\/\/www.logicbus.com.mx\/contacto.php\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" class=\"card-review\" src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/11\/soporte.png \" width=\"106\" height=\"106\" \/><\/a><a href=\"https:\/\/api.whatsapp.com\/send?phone=525554316718&amp;text=Hola%20Logicbus,me%20gustar%C3%ADa%20solicitar%20informaci%C3%B3n\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" class=\"card-review\" src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/11\/wa.png \" width=\"103\" height=\"103\" \/><\/a><a href=\"https:\/\/tawk.to\/chat\/5ca674ff1de11b6e3b06f73d\/default\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" class=\"card-review\" src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/11\/contacto.png \" width=\"115\" height=\"115\" \/><\/a><a href=\"https:\/\/www.logicbus.com.mx\/soluciones-en-la-industria-logicbus.php\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" class=\"card-review\" src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/11\/soluciones.png \" width=\"106\" height=\"106\" \/><\/a><\/div>\n<p style=\"text-align: center;\"><a href=\"mailto:ventas@logicbus.com\">ventas@logicbus.com<\/a>\u00a0 \u00a0 \u00a0 |\u00a0 \u00a0 \u00a0\u00a0<a href=\"mailto:soporte@logicbus.com\">soporte@logicbus.com<\/a>\u00a0 \u00a0 \u00a0 |\u00a0 \u00a0 \u00a0\u00a0<a href=\"https:\/\/api.whatsapp.com\/send?phone=525554316718&amp;text=Hola%20Logicbus,me%20gustar%C3%ADa%20solicitar%20informaci%C3%B3n\">55-5431-67-18<\/a>\u00a0 \u00a0 |\u00a0 \u00a0 \u00a0\u00a0<a href=\"https:\/\/tawk.to\/chat\/5ca674ff1de11b6e3b06f73d\/default\">Iniciar conversaci\u00f3n<\/a><\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>En el mundo de la automatizaci\u00f3n industrial, los t\u00e9rminos PLC, PAC e IPC se lanzan como si fueran intercambiables. El problema es que en muchos sentidos lo son. Y, a medida que avanzan las tecnolog\u00edas en las tres categor\u00edas de dispositivos, sus caracter\u00edsticas y beneficios \u00fanicos convergen y sus diferencias se vuelven menos notables. Entonces, [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":40953,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[71,5767],"tags":[],"class_list":["post-40938","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articulos","category-plcs-y-convertidores-de-protocolo"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Tecnolog\u00edas PLCs vs PACs vs IPCs &#8211; Blog Logicbus<\/title>\n<meta name=\"description\" content=\"En el mundo de la automatizaci\u00f3n industrial, los t\u00e9rminos PLC, PAC e IPC se lanzan como si fueran intercambiables. El problema es que en muchos sentidos lo\u2026\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.logicbus.com.mx\/blog\/tecnologias-plcs-vs-pacs-vs-ipcs\/\" \/>\n<meta property=\"og:locale\" content=\"es_MX\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Tecnolog\u00edas PLCs vs PACs vs IPCs &#8211; Blog Logicbus\" \/>\n<meta property=\"og:description\" content=\"En el mundo de la automatizaci\u00f3n industrial, los t\u00e9rminos PLC, PAC e IPC se lanzan como si fueran intercambiables. El problema es que en muchos sentidos lo\u2026\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.logicbus.com.mx\/blog\/tecnologias-plcs-vs-pacs-vs-ipcs\/\" \/>\n<meta property=\"og:site_name\" content=\"Blog Logicbus\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/logicbus\/\" \/>\n<meta property=\"article:published_time\" content=\"2022-11-22T18:55:50+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-05-31T17:36:58+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/11\/bbnn-4.png\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"401\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Logicbus\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"Logicbus\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutos\" \/>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Tecnolog\u00edas PLCs vs PACs vs IPCs &#8211; Blog Logicbus","description":"En el mundo de la automatizaci\u00f3n industrial, los t\u00e9rminos PLC, PAC e IPC se lanzan como si fueran intercambiables. El problema es que en muchos sentidos lo\u2026","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.logicbus.com.mx\/blog\/tecnologias-plcs-vs-pacs-vs-ipcs\/","og_locale":"es_MX","og_type":"article","og_title":"Tecnolog\u00edas PLCs vs PACs vs IPCs &#8211; Blog Logicbus","og_description":"En el mundo de la automatizaci\u00f3n industrial, los t\u00e9rminos PLC, PAC e IPC se lanzan como si fueran intercambiables. El problema es que en muchos sentidos lo\u2026","og_url":"https:\/\/www.logicbus.com.mx\/blog\/tecnologias-plcs-vs-pacs-vs-ipcs\/","og_site_name":"Blog Logicbus","article_publisher":"https:\/\/www.facebook.com\/logicbus\/","article_published_time":"2022-11-22T18:55:50+00:00","article_modified_time":"2023-05-31T17:36:58+00:00","og_image":[{"width":800,"height":401,"url":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/11\/bbnn-4.png","type":"image\/png"}],"author":"Logicbus","twitter_misc":{"Escrito por":"Logicbus","Tiempo de lectura":"5 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.logicbus.com.mx\/blog\/tecnologias-plcs-vs-pacs-vs-ipcs\/#article","isPartOf":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/tecnologias-plcs-vs-pacs-vs-ipcs\/"},"author":{"name":"Logicbus","@id":"https:\/\/www.logicbus.com.mx\/blog\/#\/schema\/person\/42451dd47a6fc9e56bb0386ab20bffd5"},"headline":"Tecnolog\u00edas PLCs vs PACs vs IPCs","datePublished":"2022-11-22T18:55:50+00:00","dateModified":"2023-05-31T17:36:58+00:00","mainEntityOfPage":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/tecnologias-plcs-vs-pacs-vs-ipcs\/"},"wordCount":911,"commentCount":0,"publisher":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/#organization"},"image":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/tecnologias-plcs-vs-pacs-vs-ipcs\/#primaryimage"},"thumbnailUrl":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/11\/bbnn-4.png","articleSection":["Articulos","PLCs y Convertidores de protocolo"],"inLanguage":"es","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.logicbus.com.mx\/blog\/tecnologias-plcs-vs-pacs-vs-ipcs\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.logicbus.com.mx\/blog\/tecnologias-plcs-vs-pacs-vs-ipcs\/","url":"https:\/\/www.logicbus.com.mx\/blog\/tecnologias-plcs-vs-pacs-vs-ipcs\/","name":"Tecnolog\u00edas PLCs vs PACs vs IPCs &#8211; Blog Logicbus","isPartOf":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/tecnologias-plcs-vs-pacs-vs-ipcs\/#primaryimage"},"image":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/tecnologias-plcs-vs-pacs-vs-ipcs\/#primaryimage"},"thumbnailUrl":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/11\/bbnn-4.png","datePublished":"2022-11-22T18:55:50+00:00","dateModified":"2023-05-31T17:36:58+00:00","description":"En el mundo de la automatizaci\u00f3n industrial, los t\u00e9rminos PLC, PAC e IPC se lanzan como si fueran intercambiables. El problema es que en muchos sentidos lo\u2026","breadcrumb":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/tecnologias-plcs-vs-pacs-vs-ipcs\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.logicbus.com.mx\/blog\/tecnologias-plcs-vs-pacs-vs-ipcs\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.logicbus.com.mx\/blog\/tecnologias-plcs-vs-pacs-vs-ipcs\/#primaryimage","url":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/11\/bbnn-4.png","contentUrl":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/11\/bbnn-4.png","width":800,"height":401},{"@type":"BreadcrumbList","@id":"https:\/\/www.logicbus.com.mx\/blog\/tecnologias-plcs-vs-pacs-vs-ipcs\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Inicio","item":"https:\/\/www.logicbus.com.mx\/blog\/"},{"@type":"ListItem","position":2,"name":"Tecnolog\u00edas PLCs vs PACs vs IPCs"}]},{"@type":"WebSite","@id":"https:\/\/www.logicbus.com.mx\/blog\/#website","url":"https:\/\/www.logicbus.com.mx\/blog\/","name":"Blog Logicbus","description":"Logicbus Blog ofrece informaci\u00f3n detallada sobre el control de procesos, sus tipos, elementos e importancia.","publisher":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.logicbus.com.mx\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/www.logicbus.com.mx\/blog\/#organization","name":"Logicbus Blog","url":"https:\/\/www.logicbus.com.mx\/blog\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.logicbus.com.mx\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/logo-logicbus-blog.png","contentUrl":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/logo-logicbus-blog.png","width":1761,"height":546,"caption":"Logicbus Blog"},"image":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/logicbus\/","https:\/\/x.com\/Logicbus"]},{"@type":"Person","@id":"https:\/\/www.logicbus.com.mx\/blog\/#\/schema\/person\/42451dd47a6fc9e56bb0386ab20bffd5","name":"Logicbus","image":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/JosueCetina-96x96.png","url":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/JosueCetina-96x96.png","contentUrl":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/JosueCetina-96x96.png","caption":"Logicbus"},"sameAs":["https:\/\/www.logicbus.com.mx\/blog","it@logicbus.com"],"url":"https:\/\/www.logicbus.com.mx\/blog\/author\/itlogicbus-com\/"}]}},"_links":{"self":[{"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/posts\/40938","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/comments?post=40938"}],"version-history":[{"count":0,"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/posts\/40938\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/media\/40953"}],"wp:attachment":[{"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/media?parent=40938"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/categories?post=40938"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/tags?post=40938"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}