{"id":45300,"date":"2025-12-29T10:15:07","date_gmt":"2025-12-29T16:15:07","guid":{"rendered":"https:\/\/www.logicbus.com.mx\/blog\/?p=45300"},"modified":"2026-02-03T11:12:47","modified_gmt":"2026-02-03T17:12:47","slug":"switches-gestionables-vs-no-gestionables-3onedata-realmente-necesito-gestion-en-mi-red","status":"publish","type":"post","link":"https:\/\/www.logicbus.com.mx\/blog\/switches-gestionables-vs-no-gestionables-3onedata-realmente-necesito-gestion-en-mi-red\/","title":{"rendered":"Switches Gestionables vs. No Gestionables (3onedata): \u00bfRealmente necesito gesti\u00f3n en mi red?"},"content":{"rendered":"<p data-start=\"371\" data-end=\"763\">En los entornos de <strong data-start=\"390\" data-end=\"419\">automatizaci\u00f3n industrial<\/strong>, la comunicaci\u00f3n de datos es tan cr\u00edtica como la energ\u00eda el\u00e9ctrica. PLCs, HMIs, sensores, c\u00e1maras industriales y sistemas SCADA dependen de redes Ethernet robustas, estables y seguras. En este contexto, elegir el <strong data-start=\"633\" data-end=\"663\">switch industrial adecuado<\/strong> puede marcar la diferencia entre una red confiable y una llena de fallos dif\u00edciles de diagnosticar.<\/p>\n<p data-start=\"765\" data-end=\"1038\">Una de las dudas m\u00e1s comunes es:<br data-start=\"797\" data-end=\"800\" \/><strong data-start=\"800\" data-end=\"857\">\u00bfnecesito un switch gestionable o uno no gestionable?<\/strong><br data-start=\"857\" data-end=\"860\" \/>En este art\u00edculo analizamos las diferencias clave entre ambos, con enfoque en los <a href=\"https:\/\/tienda.logicbus.com.mx\/Switches-Industriales_c_7833.html\"><strong data-start=\"942\" data-end=\"976\">switches industriales 3onedata<\/strong><\/a>, para ayudarte a tomar la mejor decisi\u00f3n seg\u00fan tu aplicaci\u00f3n.<\/p>\n<h2 data-start=\"1045\" data-end=\"1092\">\u00bfQu\u00e9 es un switch industrial no gestionable? <img decoding=\"async\" class=\" wp-image-45195 alignright\" src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2025\/11\/IES6210-8T2GC-2P48.webp\" alt=\"\" width=\"450\" height=\"450\" srcset=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2025\/11\/IES6210-8T2GC-2P48.webp 200w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2025\/11\/IES6210-8T2GC-2P48-150x150.webp 150w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2025\/11\/IES6210-8T2GC-2P48-24x24.webp 24w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2025\/11\/IES6210-8T2GC-2P48-48x48.webp 48w, https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2025\/11\/IES6210-8T2GC-2P48-96x96.webp 96w\" sizes=\"(max-width: 450px) 100vw, 450px\" \/><\/h2>\n<p data-start=\"1094\" data-end=\"1291\">Un <strong data-start=\"1097\" data-end=\"1122\">switch no gestionable<\/strong> es un dispositivo de red dise\u00f1ado para funcionar bajo el principio <em data-start=\"1190\" data-end=\"1203\">plug &amp; play<\/em>. Basta con conectarlo y comienza a operar de inmediato, sin necesidad de configuraci\u00f3n.<\/p>\n<h3 data-start=\"1293\" data-end=\"1324\">Caracter\u00edsticas principales<\/h3>\n<ul data-start=\"1325\" data-end=\"1467\">\n<li data-start=\"1325\" data-end=\"1358\">\n<p data-start=\"1327\" data-end=\"1358\">Instalaci\u00f3n r\u00e1pida y sencilla<\/p>\n<\/li>\n<li data-start=\"1359\" data-end=\"1417\">\n<p data-start=\"1361\" data-end=\"1417\">No requiere software ni conocimientos de red avanzados<\/p>\n<\/li>\n<li data-start=\"1418\" data-end=\"1432\">\n<p data-start=\"1420\" data-end=\"1432\">Bajo costo<\/p>\n<\/li>\n<li data-start=\"1433\" data-end=\"1467\">\n<p data-start=\"1435\" data-end=\"1467\">Operaci\u00f3n autom\u00e1tica sin ajustes<\/p>\n<\/li>\n<\/ul>\n<h3 data-start=\"1469\" data-end=\"1520\">\u00bfCu\u00e1ndo es suficiente un switch no gestionable?<\/h3>\n<p data-start=\"1521\" data-end=\"1583\">Los switches no gestionables de <a href=\"https:\/\/tienda.logicbus.com.mx\/3onedata\"><strong data-start=\"1553\" data-end=\"1565\">3onedata<\/strong><\/a> son ideales para:<\/p>\n<ul data-start=\"1584\" data-end=\"1776\">\n<li data-start=\"1584\" data-end=\"1612\">\n<p data-start=\"1586\" data-end=\"1612\">Redes peque\u00f1as o simples<\/p>\n<\/li>\n<li data-start=\"1613\" data-end=\"1661\">\n<p data-start=\"1615\" data-end=\"1661\">Aplicaciones con pocos dispositivos Ethernet<\/p>\n<\/li>\n<li data-start=\"1662\" data-end=\"1722\">\n<p data-start=\"1664\" data-end=\"1722\">Sistemas donde la prioridad es la rapidez de instalaci\u00f3n<\/p>\n<\/li>\n<li data-start=\"1723\" data-end=\"1776\">\n<p data-start=\"1725\" data-end=\"1776\">Entornos industriales b\u00e1sicos sin tr\u00e1fico cr\u00edtico<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"1778\" data-end=\"1911\">Por ejemplo, una celda de producci\u00f3n con pocos equipos o una red local aislada puede funcionar perfectamente con este tipo de switch.<\/p>\n<h2 data-start=\"1918\" data-end=\"1962\">\u00bfQu\u00e9 es un switch industrial gestionable?<\/h2>\n<p data-start=\"1964\" data-end=\"2192\">Un <strong data-start=\"1967\" data-end=\"1989\">switch gestionable<\/strong> permite <strong data-start=\"1998\" data-end=\"2036\">configurar, supervisar y optimizar<\/strong> la red mediante una interfaz web, software o protocolos industriales. No solo conecta dispositivos, sino que ofrece <strong data-start=\"2153\" data-end=\"2191\">control total del tr\u00e1fico de datos<\/strong>.<\/p>\n<h3 data-start=\"2194\" data-end=\"2233\">Funciones avanzadas m\u00e1s importantes<\/h3>\n<ul data-start=\"2234\" data-end=\"2518\">\n<li data-start=\"2234\" data-end=\"2269\">\n<p data-start=\"2236\" data-end=\"2269\"><strong data-start=\"2236\" data-end=\"2245\">VLANs<\/strong> para segmentar la red<\/p>\n<\/li>\n<li data-start=\"2270\" data-end=\"2333\">\n<p data-start=\"2272\" data-end=\"2333\"><strong data-start=\"2272\" data-end=\"2300\">QoS (Quality of Service)<\/strong> para priorizar tr\u00e1fico cr\u00edtico<\/p>\n<\/li>\n<li data-start=\"2334\" data-end=\"2368\">\n<p data-start=\"2336\" data-end=\"2368\"><strong data-start=\"2336\" data-end=\"2344\">SNMP<\/strong> para monitoreo remoto<\/p>\n<\/li>\n<li data-start=\"2369\" data-end=\"2413\">\n<p data-start=\"2371\" data-end=\"2413\"><strong data-start=\"2371\" data-end=\"2393\">Redundancia de red<\/strong> (STP, RSTP, ERPS)<\/p>\n<\/li>\n<li data-start=\"2414\" data-end=\"2454\">\n<p data-start=\"2416\" data-end=\"2454\"><strong data-start=\"2416\" data-end=\"2452\">Diagn\u00f3stico y registro de fallos<\/strong><\/p>\n<\/li>\n<li data-start=\"2455\" data-end=\"2518\">\n<p data-start=\"2457\" data-end=\"2518\"><strong data-start=\"2457\" data-end=\"2479\">Seguridad avanzada<\/strong> (control de accesos, puertos, alertas)<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"2520\" data-end=\"2689\">Los <a href=\"https:\/\/tienda.logicbus.com.mx\/Switches-Industriales_c_7833.html\">switches<\/a> gestionables <a href=\"https:\/\/tienda.logicbus.com.mx\/3onedata\"><strong data-start=\"2546\" data-end=\"2558\">3onedata<\/strong><\/a> est\u00e1n dise\u00f1ados para entornos industriales exigentes, soportando vibraciones, temperaturas extremas y comunicaci\u00f3n ininterrumpida.<\/p>\n<h2 data-start=\"2696\" data-end=\"2749\">Comparativa r\u00e1pida: Gestionable vs. No gestionable<\/h2>\n<div class=\"TyagGW_tableContainer\">\n<div class=\"group TyagGW_tableWrapper flex w-fit flex-col-reverse\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" style=\"height: 244px;\" width=\"1368\" data-start=\"2751\" data-end=\"3074\">\n<thead data-start=\"2751\" data-end=\"2800\">\n<tr data-start=\"2751\" data-end=\"2800\">\n<th data-start=\"2751\" data-end=\"2768\" data-col-size=\"sm\">Caracter\u00edstica<\/th>\n<th data-start=\"2768\" data-end=\"2785\" data-col-size=\"sm\">No gestionable<\/th>\n<th data-start=\"2785\" data-end=\"2800\" data-col-size=\"sm\">Gestionable<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"2850\" data-end=\"3074\">\n<tr data-start=\"2850\" data-end=\"2877\">\n<td data-start=\"2850\" data-end=\"2866\" data-col-size=\"sm\">Configuraci\u00f3n<\/td>\n<td data-col-size=\"sm\" data-start=\"2866\" data-end=\"2871\">No<\/td>\n<td data-col-size=\"sm\" data-start=\"2871\" data-end=\"2877\">S\u00ed<\/td>\n<\/tr>\n<tr data-start=\"2878\" data-end=\"2908\">\n<td data-start=\"2878\" data-end=\"2897\" data-col-size=\"sm\">Monitoreo de red<\/td>\n<td data-col-size=\"sm\" data-start=\"2897\" data-end=\"2902\">No<\/td>\n<td data-col-size=\"sm\" data-start=\"2902\" data-end=\"2908\">S\u00ed<\/td>\n<\/tr>\n<tr data-start=\"2909\" data-end=\"2946\">\n<td data-start=\"2909\" data-end=\"2935\" data-col-size=\"sm\">Priorizaci\u00f3n de tr\u00e1fico<\/td>\n<td data-col-size=\"sm\" data-start=\"2935\" data-end=\"2940\">No<\/td>\n<td data-col-size=\"sm\" data-start=\"2940\" data-end=\"2946\">S\u00ed<\/td>\n<\/tr>\n<tr data-start=\"2947\" data-end=\"2972\">\n<td data-start=\"2947\" data-end=\"2961\" data-col-size=\"sm\">Redundancia<\/td>\n<td data-col-size=\"sm\" data-start=\"2961\" data-end=\"2966\">No<\/td>\n<td data-col-size=\"sm\" data-start=\"2966\" data-end=\"2972\">S\u00ed<\/td>\n<\/tr>\n<tr data-start=\"2973\" data-end=\"3006\">\n<td data-start=\"2973\" data-end=\"2985\" data-col-size=\"sm\">Seguridad<\/td>\n<td data-col-size=\"sm\" data-start=\"2985\" data-end=\"2994\">B\u00e1sica<\/td>\n<td data-col-size=\"sm\" data-start=\"2994\" data-end=\"3006\">Avanzada<\/td>\n<\/tr>\n<tr data-start=\"3007\" data-end=\"3038\">\n<td data-start=\"3007\" data-end=\"3015\" data-col-size=\"sm\">Costo<\/td>\n<td data-col-size=\"sm\" data-start=\"3015\" data-end=\"3026\">M\u00e1s bajo<\/td>\n<td data-col-size=\"sm\" data-start=\"3026\" data-end=\"3038\">M\u00e1s alto<\/td>\n<\/tr>\n<tr data-start=\"3039\" data-end=\"3074\">\n<td data-start=\"3039\" data-end=\"3055\" data-col-size=\"sm\">Escalabilidad<\/td>\n<td data-col-size=\"sm\" data-start=\"3055\" data-end=\"3066\">Limitada<\/td>\n<td data-col-size=\"sm\" data-start=\"3066\" data-end=\"3074\">Alta<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<h2 data-start=\"3081\" data-end=\"3127\">\u00bfRealmente necesitas un switch gestionable?<\/h2>\n<p data-start=\"3129\" data-end=\"3218\">La respuesta depende del <strong data-start=\"3154\" data-end=\"3187\">nivel de criticidad de tu red<\/strong>. Aqu\u00ed algunas preguntas clave:<\/p>\n<h3 data-start=\"3220\" data-end=\"3259\">Considera un switch gestionable si:<\/h3>\n<ul data-start=\"3260\" data-end=\"3516\">\n<li data-start=\"3260\" data-end=\"3300\">\n<p data-start=\"3262\" data-end=\"3300\">Tu red es grande o seguir\u00e1 creciendo<\/p>\n<\/li>\n<li data-start=\"3301\" data-end=\"3342\">\n<p data-start=\"3303\" data-end=\"3342\">Manejas datos cr\u00edticos en tiempo real<\/p>\n<\/li>\n<li data-start=\"3343\" data-end=\"3390\">\n<p data-start=\"3345\" data-end=\"3390\">Necesitas alta disponibilidad y redundancia<\/p>\n<\/li>\n<li data-start=\"3391\" data-end=\"3435\">\n<p data-start=\"3393\" data-end=\"3435\">Requieres diagn\u00f3stico r\u00e1pido ante fallos<\/p>\n<\/li>\n<li data-start=\"3436\" data-end=\"3472\">\n<p data-start=\"3438\" data-end=\"3472\">Buscas mayor seguridad y control<\/p>\n<\/li>\n<li data-start=\"3473\" data-end=\"3516\">\n<p data-start=\"3475\" data-end=\"3516\">Integras la red a sistemas SCADA o IIoT<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"3518\" data-end=\"3719\">En plantas industriales, l\u00edneas automatizadas, subestaciones el\u00e9ctricas, transporte inteligente o infraestructura cr\u00edtica, un <strong data-start=\"3644\" data-end=\"3718\">switch gestionable deja de ser un lujo y se convierte en una necesidad<\/strong>.<\/p>\n<h2 data-start=\"3726\" data-end=\"3791\">\u00bfCu\u00e1ndo un switch no gestionable sigue siendo la mejor opci\u00f3n?<\/h2>\n<p data-start=\"3793\" data-end=\"3893\">A pesar de las ventajas de la gesti\u00f3n, los switches no gestionables siguen siendo muy \u00fatiles cuando:<\/p>\n<ul data-start=\"3894\" data-end=\"4019\">\n<li data-start=\"3894\" data-end=\"3925\">\n<p data-start=\"3896\" data-end=\"3925\">La red es peque\u00f1a y estable<\/p>\n<\/li>\n<li data-start=\"3926\" data-end=\"3952\">\n<p data-start=\"3928\" data-end=\"3952\">No hay tr\u00e1fico cr\u00edtico<\/p>\n<\/li>\n<li data-start=\"3953\" data-end=\"3980\">\n<p data-start=\"3955\" data-end=\"3980\">Se busca reducir costos<\/p>\n<\/li>\n<li data-start=\"3981\" data-end=\"4019\">\n<p data-start=\"3983\" data-end=\"4019\">No se requiere monitoreo constante<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"4021\" data-end=\"4157\">En estos casos, los switches industriales no gestionables de <a href=\"https:\/\/tienda.logicbus.com.mx\/3onedata\"><strong data-start=\"4082\" data-end=\"4094\">3onedata<\/strong><\/a> ofrecen <strong data-start=\"4103\" data-end=\"4156\">fiabilidad industrial sin complejidad innecesaria<\/strong>.<\/p>\n<h2 data-start=\"4164\" data-end=\"4220\">3onedata: soluciones para cada tipo de red industrial<\/h2>\n<p data-start=\"4222\" data-end=\"4337\"><a href=\"https:\/\/tienda.logicbus.com.mx\/3onedata\">3onedata<\/a> ofrece un portafolio completo de <a href=\"https:\/\/tienda.logicbus.com.mx\/Switches-Industriales_c_7833.html\"><strong data-start=\"4264\" data-end=\"4320\">switches industriales gestionables y no gestionables<\/strong><\/a>, dise\u00f1ados para:<\/p>\n<ul data-start=\"4338\" data-end=\"4472\">\n<li data-start=\"4338\" data-end=\"4367\">\n<p data-start=\"4340\" data-end=\"4367\">Automatizaci\u00f3n industrial<\/p>\n<\/li>\n<li data-start=\"4368\" data-end=\"4395\">\n<p data-start=\"4370\" data-end=\"4395\">Energ\u00eda y subestaciones<\/p>\n<\/li>\n<li data-start=\"4396\" data-end=\"4422\">\n<p data-start=\"4398\" data-end=\"4422\">Transporte inteligente<\/p>\n<\/li>\n<li data-start=\"4423\" data-end=\"4447\">\n<p data-start=\"4425\" data-end=\"4447\">Manufactura avanzada<\/p>\n<\/li>\n<li data-start=\"4448\" data-end=\"4472\">\n<p data-start=\"4450\" data-end=\"4472\">Infraestructura IIoT<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"4474\" data-end=\"4608\">Esto permite seleccionar exactamente el equipo adecuado seg\u00fan el nivel de control, seguridad y rendimiento que requiera cada proyecto.<\/p>\n<p data-start=\"4630\" data-end=\"4993\">No todas las redes industriales necesitan gesti\u00f3n avanzada, pero <strong data-start=\"4695\" data-end=\"4742\">todas necesitan estabilidad y confiabilidad<\/strong>.<br data-start=\"4743\" data-end=\"4746\" \/>Si tu aplicaci\u00f3n es sencilla, un switch no gestionable puede ser suficiente. Sin embargo, si tu red es cr\u00edtica, escalable o estrat\u00e9gica, un <strong data-start=\"4886\" data-end=\"4917\">switch gestionable 3onedata<\/strong> te brindar\u00e1 el control y la seguridad necesarios para operar sin sorpresas.<\/p>\n<p data-start=\"4995\" data-end=\"5171\">Elegir correctamente desde el inicio no solo mejora el desempe\u00f1o de la red, sino que <strong data-start=\"5080\" data-end=\"5170\">reduce tiempos muertos, facilita el mantenimiento y protege tu inversi\u00f3n a largo plazo<\/strong>.<\/p>\n<h3 style=\"text-align: center;\">Cont\u00e1ctanos<\/h3>\n<h3 style=\"text-align: center;\"><a href=\"https:\/\/tienda.logicbus.com.mx\/\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" class=\"card-review alignnone ls-is-cached lazyloaded\" title=\"Tienda en linea\" src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/11\/tienda.png\" alt=\"\" width=\"102\" height=\"102\" data-src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/11\/tienda.png\" \/><\/a><a href=\"https:\/\/www.logicbus.com.mx\/\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" class=\"card-review alignnone ls-is-cached lazyloaded\" title=\"Logicbus\" src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/11\/www.png\" alt=\"\" width=\"104\" height=\"104\" data-src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/11\/www.png\" \/><\/a><a href=\"https:\/\/www.logicbus.com.mx\/soporte\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" class=\"card-review alignnone ls-is-cached lazyloaded\" title=\"Soporte\" src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/11\/soporte.png\" alt=\"\" width=\"106\" height=\"106\" data-src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/11\/soporte.png\" \/><\/a><a href=\"https:\/\/api.whatsapp.com\/send?phone=525554316718&amp;text=Hola%20Logicbus,me%20gustar%C3%ADa%20solicitar%20informaci%C3%B3n\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" class=\"card-review alignnone ls-is-cached lazyloaded\" title=\"Whatsapp\" src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/11\/wa.png\" alt=\"\" width=\"103\" height=\"103\" data-src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/11\/wa.png\" \/><\/a><a href=\"https:\/\/www.logicbus.com.mx\/contacto\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" class=\"card-review alignnone ls-is-cached lazyloaded\" title=\"Contacto\" src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/11\/contacto.png\" alt=\"\" width=\"115\" height=\"115\" data-src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/11\/contacto.png\" \/><\/a><a href=\"https:\/\/www.logicbus.com.mx\/soluciones-en-la-industria-logicbus.php\" target=\"_blank\" rel=\"noopener\"><img decoding=\"async\" class=\"card-review alignnone ls-is-cached lazyloaded\" title=\"Soluciones\" src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/11\/soluciones.png\" alt=\"\" width=\"106\" height=\"106\" data-src=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2022\/11\/soluciones.png\" \/><\/a><\/h3>\n<p style=\"text-align: center;\"><a href=\"mailto:ventas@logicbus.com\">ventas@logicbus.com<\/a>\u00a0 \u00a0 \u00a0 |\u00a0 \u00a0 \u00a0\u00a0<a href=\"mailto:soporte@logicbus.com\">soporte@logicbus.com<\/a>\u00a0 \u00a0 \u00a0 |\u00a0 \u00a0 \u00a0\u00a0<a href=\"https:\/\/api.whatsapp.com\/send?phone=525554316718&amp;text=Hola%20Logicbus,me%20gustar%C3%ADa%20solicitar%20informaci%C3%B3n\">55-5431-67-18<\/a>\u00a0 \u00a0 |\u00a0 \u00a0 \u00a0\u00a0\u00a0<a href=\"https:\/\/tawk.to\/chat\/5ca674ff1de11b6e3b06f73d\/default\">Iniciar conversaci\u00f3n<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>En los entornos de automatizaci\u00f3n industrial, la comunicaci\u00f3n de datos es tan cr\u00edtica como la energ\u00eda el\u00e9ctrica. PLCs, HMIs, sensores, c\u00e1maras industriales y sistemas SCADA dependen de redes Ethernet robustas, estables y seguras. En este contexto, elegir el switch industrial adecuado puede marcar la diferencia entre una red confiable y una llena de fallos dif\u00edciles [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":45302,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[71],"tags":[],"class_list":["post-45300","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articulos"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Switches Gestionables vs. No Gestionables (3onedata)<\/title>\n<meta name=\"description\" content=\"En los entornos de automatizaci\u00f3n industrial, la comunicaci\u00f3n de datos es tan cr\u00edtica como la energ\u00eda el\u00e9ctrica.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.logicbus.com.mx\/blog\/switches-gestionables-vs-no-gestionables-3onedata-realmente-necesito-gestion-en-mi-red\/\" \/>\n<meta property=\"og:locale\" content=\"es_MX\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Switches Gestionables vs. No Gestionables (3onedata)\" \/>\n<meta property=\"og:description\" content=\"En los entornos de automatizaci\u00f3n industrial, la comunicaci\u00f3n de datos es tan cr\u00edtica como la energ\u00eda el\u00e9ctrica.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.logicbus.com.mx\/blog\/switches-gestionables-vs-no-gestionables-3onedata-realmente-necesito-gestion-en-mi-red\/\" \/>\n<meta property=\"og:site_name\" content=\"Blog Logicbus\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/logicbus\/\" \/>\n<meta property=\"article:published_time\" content=\"2025-12-29T16:15:07+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-02-03T17:12:47+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2025\/12\/Switches-Gestionables-vs.-No-Gestionables-_3onedata_-\u00bfRealmente-necesito-gestion-en-mi-red.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"2560\" \/>\n\t<meta property=\"og:image:height\" content=\"1280\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"Logicbus\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\" \/>\n\t<meta name=\"twitter:data1\" content=\"Logicbus\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutos\" \/>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Switches Gestionables vs. No Gestionables (3onedata)","description":"En los entornos de automatizaci\u00f3n industrial, la comunicaci\u00f3n de datos es tan cr\u00edtica como la energ\u00eda el\u00e9ctrica.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.logicbus.com.mx\/blog\/switches-gestionables-vs-no-gestionables-3onedata-realmente-necesito-gestion-en-mi-red\/","og_locale":"es_MX","og_type":"article","og_title":"Switches Gestionables vs. No Gestionables (3onedata)","og_description":"En los entornos de automatizaci\u00f3n industrial, la comunicaci\u00f3n de datos es tan cr\u00edtica como la energ\u00eda el\u00e9ctrica.","og_url":"https:\/\/www.logicbus.com.mx\/blog\/switches-gestionables-vs-no-gestionables-3onedata-realmente-necesito-gestion-en-mi-red\/","og_site_name":"Blog Logicbus","article_publisher":"https:\/\/www.facebook.com\/logicbus\/","article_published_time":"2025-12-29T16:15:07+00:00","article_modified_time":"2026-02-03T17:12:47+00:00","og_image":[{"width":2560,"height":1280,"url":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2025\/12\/Switches-Gestionables-vs.-No-Gestionables-_3onedata_-\u00bfRealmente-necesito-gestion-en-mi-red.webp","type":"image\/webp"}],"author":"Logicbus","twitter_misc":{"Escrito por":"Logicbus","Tiempo de lectura":"5 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.logicbus.com.mx\/blog\/switches-gestionables-vs-no-gestionables-3onedata-realmente-necesito-gestion-en-mi-red\/#article","isPartOf":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/switches-gestionables-vs-no-gestionables-3onedata-realmente-necesito-gestion-en-mi-red\/"},"author":{"name":"Logicbus","@id":"https:\/\/www.logicbus.com.mx\/blog\/#\/schema\/person\/42451dd47a6fc9e56bb0386ab20bffd5"},"headline":"Switches Gestionables vs. No Gestionables (3onedata): \u00bfRealmente necesito gesti\u00f3n en mi red?","datePublished":"2025-12-29T16:15:07+00:00","dateModified":"2026-02-03T17:12:47+00:00","mainEntityOfPage":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/switches-gestionables-vs-no-gestionables-3onedata-realmente-necesito-gestion-en-mi-red\/"},"wordCount":719,"publisher":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/#organization"},"image":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/switches-gestionables-vs-no-gestionables-3onedata-realmente-necesito-gestion-en-mi-red\/#primaryimage"},"thumbnailUrl":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2025\/12\/Switches-Gestionables-vs.-No-Gestionables-_3onedata_-\u00bfRealmente-necesito-gestion-en-mi-red.webp","articleSection":["Articulos"],"inLanguage":"es"},{"@type":"WebPage","@id":"https:\/\/www.logicbus.com.mx\/blog\/switches-gestionables-vs-no-gestionables-3onedata-realmente-necesito-gestion-en-mi-red\/","url":"https:\/\/www.logicbus.com.mx\/blog\/switches-gestionables-vs-no-gestionables-3onedata-realmente-necesito-gestion-en-mi-red\/","name":"Switches Gestionables vs. No Gestionables (3onedata)","isPartOf":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/switches-gestionables-vs-no-gestionables-3onedata-realmente-necesito-gestion-en-mi-red\/#primaryimage"},"image":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/switches-gestionables-vs-no-gestionables-3onedata-realmente-necesito-gestion-en-mi-red\/#primaryimage"},"thumbnailUrl":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2025\/12\/Switches-Gestionables-vs.-No-Gestionables-_3onedata_-\u00bfRealmente-necesito-gestion-en-mi-red.webp","datePublished":"2025-12-29T16:15:07+00:00","dateModified":"2026-02-03T17:12:47+00:00","description":"En los entornos de automatizaci\u00f3n industrial, la comunicaci\u00f3n de datos es tan cr\u00edtica como la energ\u00eda el\u00e9ctrica.","breadcrumb":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/switches-gestionables-vs-no-gestionables-3onedata-realmente-necesito-gestion-en-mi-red\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.logicbus.com.mx\/blog\/switches-gestionables-vs-no-gestionables-3onedata-realmente-necesito-gestion-en-mi-red\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.logicbus.com.mx\/blog\/switches-gestionables-vs-no-gestionables-3onedata-realmente-necesito-gestion-en-mi-red\/#primaryimage","url":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2025\/12\/Switches-Gestionables-vs.-No-Gestionables-_3onedata_-\u00bfRealmente-necesito-gestion-en-mi-red.webp","contentUrl":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2025\/12\/Switches-Gestionables-vs.-No-Gestionables-_3onedata_-\u00bfRealmente-necesito-gestion-en-mi-red.webp","width":1920,"height":960},{"@type":"BreadcrumbList","@id":"https:\/\/www.logicbus.com.mx\/blog\/switches-gestionables-vs-no-gestionables-3onedata-realmente-necesito-gestion-en-mi-red\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Inicio","item":"https:\/\/www.logicbus.com.mx\/blog\/"},{"@type":"ListItem","position":2,"name":"Switches Gestionables vs. No Gestionables (3onedata): \u00bfRealmente necesito gesti\u00f3n en mi red?"}]},{"@type":"WebSite","@id":"https:\/\/www.logicbus.com.mx\/blog\/#website","url":"https:\/\/www.logicbus.com.mx\/blog\/","name":"Blog Logicbus","description":"Logicbus Blog ofrece informaci\u00f3n detallada sobre el control de procesos, sus tipos, elementos e importancia.","publisher":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.logicbus.com.mx\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/www.logicbus.com.mx\/blog\/#organization","name":"Logicbus Blog","url":"https:\/\/www.logicbus.com.mx\/blog\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.logicbus.com.mx\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/logo-logicbus-blog.png","contentUrl":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/logo-logicbus-blog.png","width":1761,"height":546,"caption":"Logicbus Blog"},"image":{"@id":"https:\/\/www.logicbus.com.mx\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/logicbus\/","https:\/\/x.com\/Logicbus"]},{"@type":"Person","@id":"https:\/\/www.logicbus.com.mx\/blog\/#\/schema\/person\/42451dd47a6fc9e56bb0386ab20bffd5","name":"Logicbus","image":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/JosueCetina-96x96.png","url":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/JosueCetina-96x96.png","contentUrl":"https:\/\/www.logicbus.com.mx\/blog\/wp-content\/uploads\/2021\/03\/JosueCetina-96x96.png","caption":"Logicbus"},"sameAs":["https:\/\/www.logicbus.com.mx\/blog","it@logicbus.com"],"url":"https:\/\/www.logicbus.com.mx\/blog\/author\/itlogicbus-com\/"}]}},"_links":{"self":[{"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/posts\/45300","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/comments?post=45300"}],"version-history":[{"count":0,"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/posts\/45300\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/media\/45302"}],"wp:attachment":[{"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/media?parent=45300"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/categories?post=45300"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.logicbus.com.mx\/blog\/wp-json\/wp\/v2\/tags?post=45300"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}